Removing The Cartridge Group; Fig. 22: Do Not Loosen Screw Plugs - ABB HT600042 Operation Manual

Table of Contents

Advertisement

Operation Manual / 4 Product description / TPS44-H.. - TPS52-H..
9 Dismantling and fitting / 9.6 Removing the cartridge group
9.6

Removing the cartridge group

Do not remove oil orifice (if present)
To limit the oil flow rate through the bearing casing during operation (engine under load) to
the admissible values, an oil orifice is mandatory at the oil inlet of the bearing casing if the
oil inlet pressure is > 3 bar (overpressure).
If an oil orifice is fitted in the oil inlet of the bearing casing, it must not be removed.
Do not loosen screw plugs
CAUTION
Oil leaks
These screw plugs must not be removed for maintenance work. If a screw
plug is loosened, the gasket can be damaged. This can result in an oil leak.
Do not loosen screw plugs.
u
If any screw plugs have been loosened accidentally, have these properly
u
fitted by an ABB Turbocharging Service Station.
Fig. 22: Do not loosen screw plugs
© Copyright 2017 ABB. All rights reserved.
42001
Bearing casing
42196
Oil orifice in the oil inlet
HZTL4037_EN
Revision E
July 2017