ABB HT600042 Operation Manual page 62

Table of Contents

Advertisement

Operation Manual / 4 Product description / TPS44-H.. - TPS52-H..
7 Periodic maintenance work / 7.2 Cleaning components mechanically
Cleaning the absorption segments
(see Fig. 13: Cleaning the filter silencer →31)
Loosen the tension bands (81270).
u
Remove the cover grid (81266).
u
Pull out and bend up the sheet-metal coverings (81137), and remove the absorption seg-
u
ments (81136).
Clean the absorption segments (81136).
u
When cleaning, note that the absorption segments (81136) must only be cleaned lightly
with compressed air, a soft brush or a moist cleaning cloth.
Have any heavily contaminated absorption segments replaced by an ABB Turbocharging
u
Service Station.
Fitting the filter silencer
(see Fig. 13: Cleaning the filter silencer →31)
Insert the absorption segments (81136) into the sheet-metal coverings (81137).
u
Bend the sheet-metal coverings (81137) back to their original shape and insert into the
u
slotted guides in the filter silencer body (81135).
Fit the cover grid (81266).
u
Fit the tension bands (81270) and tighten them at the locks (81271).
u
Any tension bands that have become damaged must be replaced.
u
Fit the filter ring (81265), if present.
u
© Copyright 2017 ABB. All rights reserved.