When AC power is applied, the luminaire immediately begins a calibration sequence that steps it through full
pan and tilt movements. The internal color and beam mechanisms will also move through a full range of motion.
After calibration, the luminaire head will either stop at its "home" position (which positions the pan axis at
mid-rotation and the head parallel to the yoke with the lens pointing away from the luminaire enclosure) or
move to its current DMX-defined position if DMX data is present. All internal mechanisms also move to their
"home" or DMX-defined positions.
CAUTION: Before applying power, be sure the luminaire is hung (or positioned), and the pan and tilt locks are
disengaged, so that the head and yoke can move freely without restriction.
to power up:
Step 1.
At each luminaire, apply power connecting the power cable to the unit.
Step 2.
Luminaire automatically steps through calibration and stops at "home" position (only if DMX is not
present).
ADDRESSING

PROGRAM STARTING ADDRESS

The address setting for DMX console controlled systems is entered using the Menu Display. The luminaire retains
the DMX address even if power is removed.
DmX aDDress
to set, edit, and save a DmX address:
Step 1.
Press [ESC].
Step 2.
Press [Up] / [Down] arrows until Address appears. Press [OK].
Step 3.
Use [Left] and [Right] arrow buttons to scroll through all digits.
Step 4.
Once at desired digit, use [Up] and [Down] arrows to change highlighted digit.
Step 5.
Once digit is set, use [Left] and [Right] arrow buttons to set other digits in DMX address.
Step 6.
Once all digits are set in DMX address, press [OK] to set.
Step 7.
DMX will display and is saved.
PROGRAM STARTING ADDRESS WITHOUT CALIBRATION
It is possible to bypass the calibration sequence and go directly to the Menu Display programming in order to
pre-program an address setting.
Program starting address without calibrating luminaire:
• While powering up luminaire, press and hold [ESC].
• When display changes from "Starting" to the DMX address, program address as in Program Starting
Address above.
NOTE: The luminaire will require a reset to restore control.
Program starting address in Battery Mode:
• To activate menu in Battery Mode when the fixture is not connected to a power source, press [OK] and
[ESC] together. The LCD screen will come on. Address the fixture as described above. The LCD screen
will shut off after one minute of inactivity.
TRANSPORTING
When shipping or transporting luminaires, Vari-Lite recommends that the luminaire(s) be sufficiently protected