Diagnostic Programming Mode Flow Chart - Watts HC-300 Manual

3" commercial water softeners
Table of Contents

Advertisement

Diagnostic Programming Mode Flow Chart

Diagnostic Programming Mode
1. Press and hold the Left button to enter Diagnostic
Programming mode.
2. To navigate, press the Extra Cycle button to advance to the next
value. Press the Left button to retreat to the previous value.
3. Where applicable, use the Up and Down buttons to adjust a
value as desired.
4. To reset/clear a value (such as Totalizer or Error Log), while
on the value, press and hold the Up and Down buttons
simultaneously.
5. After progressing through all available values, the controller will
return to normal operation.
6. To exit diagnostic mode, press and hold the Left button at
anytime or after 5 minutes of inactivity the controller will return
to normal operation automatically.
7. Depending on the current controller programming, certain
values may not be able to be viewed or modified.
8. The controller will display local information, not system
information.
9. In the event of a regeneration occurring while displaying
diagnostics, the regeneration step and time remaining will
be displayed. When regeneration has been completed, the
display will return to the main screen.
Example:
Real-time flow rate reading
Example:
Peak flow since last regeneration
Example:
Gallons at the outlet since installation
Example:
Reserve Capacity setting
Example:
Gallons at the outlet since last regeneration
Example:
Time since last regeneration
Example:
Installed software version
Example:
Total number of regenerations since installation
Example:
Duration between regenerations
Example:
Last time programming settings were changed.
24
Example:
Record of error events chronologically
Example:
Average usage from past Sunday
Example:
Average usage from past 3 Sundays
Example:
Average usage from past Monday
Example:
Average usage from past 3 Mondays
Example:
Average usage from last Tuesday
Example:
Average usage from past 3 Tuesdays
Example:
Average usage from last Wednesday
Example:
Average usage from past 3 Wednesdays
Example:
Average usage from last Thursday
Example:
Average usage from past 3 Thursdays
Example:
Average usage from last Friday
Example:
Average usage from past 3 Fridays.
Example:
Average usage from last Saturdays
Example:
Average usage from past 3 Saturdays

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hcta-300Hcp-300

Table of Contents