Anti-scale system chemical-free, salt-free scale prevention (21 pages)
Summary of Contents for Watts HCTA-200-PPSM
Page 1
IOM-WQ-HC200-PPSM Installation, Operation and Maintenance 2" to 4" Commercial Water Softeners Series: HCTA-200-PPSM & HCP-200-PPSM Series HCTA-200-PPSM Duplex Alternating Series HCP-200-PPSM Progressive Systems...
Page 2
Congratulations on your purchase of this Watts commercial water softening solution. ® You have made a great choice to protect your plumbing system against the damaging effects of hard water. This system has been engineered for trouble free operation and produced using top quality components. Simple programming, corrosion resistant mineral tank(s) and an easy to service design ensures this system will be durable and easy to maintain.
If you are unsure about installing your Watts water softener • To disconnect power, unplug the AC adapter from its power contact a Watts representative or consult a professional water source.
Installation Diagrams - increase in soap and cleaning product usage. Series HCTA-200-PPSM Duplex Alternating Systems ..13 Ion exchange water softening is a process where an ion Installation Diagrams - exchange resin is used to effectively exchange calcium and Series HCP-200-PPSM 2-4 Tank Progressive Systems .
Project Data Sheet Job Details Job Number: _____________________________________________ Model Number: __________________________________________ Water Hardness: _______________ppm or gpg Capacity Per Unit: Mineral Tank Size: _____________Diameter: _____________ Height: Salt Setting per Regeneration: Regenerant Flow:_____________Upflow _____________ Downflow 1. Meter Size: A. 3/4" Paddle Wheel B.
System Specifications Dimensions - Weights Series HCTA-200-PPSM Duplex Alternating FRONT SIDE Series HCP-200-PPSM Progressive Systems FRONT SIDE Series HCTA-200-PPSM Duplex Alternating MODEL NO. DIMENSIONS WEIGHTS lbs. kgs. M4048TA-PPSM 721/2 1842 1448 2210 1067 2083 1041 1956 1700 M4052TA-PPSM 751/2 1918...
Page 8
System Specifications General System Information for Skid Mounted Pre-Plumbed Duplex Alternating HCTA-200-PPSM Softeners SPACE REQUIRED SHIPPING MODEL NO. ORDERING CODES DESCRIPTION WEIGHT D X W X H M4048TA-PPSM 68110283 5 Cubic Foot Duplex Alternating Skid Mounted Softener with Flow Meter 74"...
Hardness (maximum) ... Depends on customer’s series number. If any components are missing or damaged acceptable hardness contact your Watts representative. If they can not be reached leakage level contact Watts customer service at 800-659-8400.
If O-ring lubricant is required, only use a silicone based compound formulated for potable water O-ring applica- tions. Watts recommends Ordering Code #68102757 Silicone Lubricant. The use of other types of lubricants may attack the control’s plastic or rubber components. Petroleum-based lubricants can cause swelling in rubber parts, including O-rings and seals.
Page 11
System Installation General Installation Instructions 4j. Place the distributor tube, screen end down, into the miner- al tank and center it in the bottom. The top of the distributor 1. Turn off water heater(s). tube should be flush with the top of the tank. Test the tape cap to make sure it can not come off during the media 2.
6*. Install an inlet water sample port in the supply line and close it. valves are in the closed position and the treated water faucet 7*. If risk of vacuum exists, install Watts # 0556031 vacuum hot and cold side are in the open position.
Drain water out to drain 6. Provided system shall not be subject to any vacuum. If risk of vacuum is present, install siphon break on drain line & install vacuum relief valve watts ordering code # 0556031 on inlet line.
Wire Harness Meter Cable Power Supply 44404 Rev A 3150/3900 Valves: Communication Cables Wire Harness Hinge Mount: mount per valve model noted Meter Cable Power Supply 44403 Rev A *HCTA-200-PPSM & HCP-200-PPSM Systems use 2900/2900S Type Control Valves.
- Last Regeneration Filter - Identifiable Software Version - Total Number of Regenerations - Regeneration Interval - Last Settings Change - Error Log History - Average Daily Usage (per weekday, 3 month history) *HCTA-200-PPSM & HCP-200-PPSM Systems use 2900/2900S Type Control Valves.
Controller Operation Setting the Time of Day Note: Set Time of Day on any unit and the rest of the units in the system will update the Time of Day automatically. 1. Press and hold the Up button for 2 seconds. The “Time” value is displayed.
Controller Features Remote Lock Regeneration Types The controller does not allow the unit/system to go into Softener/Filter Meter Delayed - When volume remaining Regeneration until the Regeneration Lockout Input signal to the reaches zero and the scheduled regeneration time is reached unit is cleared.
Page 21
Regeneration at a time. System 7 (2 Units) Alternating Immediate Program all HCTA-200-PPSM Series Systems as System 7. One tank online supplying treated water, one tank in Standby. Only #1 control will monitor its flow meter/sensor input.
5 minutes of inactivity the controller Example: will exit automatically. To exit master programming without 2510, 2750, 2815, 2900, 3150, 3900: HCTA-200-PPSM & HCP-200-PPSM Systems use 2900/2900S Type Control saving changes, press the Left button until you return to the Valves.
Diagnostic Programming Mode Flow Chart Diagnostic Programming Mode Example: 1. Press and hold the Left button to enter Diagnostic Record of error events chronologically Programming mode. 2. To navigate, press the Extra Cycle button to advance to the next value. Press the Left button to retreat to the previous value. Example: 3.
Time of Day Programming Mode Flow Chart Setting the Time of Day NOTE: Set Time of Day on any unit and the rest of the units in the system will update the Time of Day automatically. 1. Press and hold the Up button for 2 seconds. The “Time” value is displayed.
NXT2 Programming Parameters and Ranges SYSTEM TYPE PROGRAMMING PARAMETER RANGES SOFTENER/ SOFTENER/ PROGRESSIVE TIME FILTER FILTER REGEN TYPE OF THE INTERLOCK SERIES ALTERNATING ALTERNATING ALTERNATING DEMAND METRIC CLOCK METERED METERED WEEK RECALL IMMEDIATE DELAYED Settings Review On, Off English Francais Deutsch Language Italiano...
Replacing the Media NOTICE to maintain the siphon. The bag will retain the resin while the water flows down the drain. Use caution not to allow resin to Ion exchange resin may need to be replaced periodically enter the floor drain. due to physical breakdown caused by chlorine/chloramine disinfectants, or fouling caused by certain metals such as 15.
Replacement Parts - Major System Components MAJOR SYSTEM COMPONENTS ITEM NO. ORDERING CODES DESCRIPTION 68103823 K4017-NT VLV 2900/1710 120V NHWBP FOR ALTERNATING & PROGRESSIVE MODELS W/ 18" & LARGER MINERAL TANK 68104397 K4519791-02 ELECTRONIC METER CABLE 35" 68108492 V2003-MCH-02 PVC DRAIN FLOW CONTROL PVC 1" HOUSING F/ 5-10 GPM BUTTONS 68108488 V2003-A-MCH-02 PVC DRAIN FLOW CONTROL PVC 1"...
Page 29
68100706 C1038 FIBERGLASS MINERAL TANK 36X72 ALMOND W/ 6" FLANGE TOP 68100326 A4000 SOFTENING RESIN MEDIA WATTS BRAND HIGH CAPACITY SAC NA FORM 1 CUBIC FOOT PER BAG 68100354 A7005A MEDIA GRAVEL #20 FLINT .06"X.125" 50 LBS PER BAG 68100356 A7006A MEDIA GRAVEL .25"X.125"...
NXT to NXT2 Conversion Kit NXT TO NXT2 CONVERSION KIT ITEM NO. PART NUMBER DESCRIPTION 68104778 K4562121-01 CONTROLLER ASSY CONV KIT NXT TO NXT2 W/ 24V US POWER SUPPLY...
Replacement Parts - 2900 Lower Powerhead 2900 LOWER POWERHEAD ITEM NO. PART NUMBER DESCRIPTION 68104635 K4560411-NT LOWER POWERHEAD F/ 2900S 24V NTXT2, NO COVER 68104574 K4560217-02 COVER FOR 2900 LOWER POWER HEAD ENVIRO...
Replacement Parts - 2900S Control Valve Body 2900S DOWNFLOW CONTROL VALVE BODY ASSEMBLY ITEM NO. ORDERING CODES DESCRIPTION VALVE BODY 2900S MACHINED, NPT U.S. TAP 68104729 K4561530 SEAL & SPACER KIT F/ 2900S UPPER 68104731 K4561540 PISTON ASSEMBLY DOWNFLOW F/ 2900S UPPER 68104546 K4560128 SEAL &...
Replacement Parts - 2" Stainless Steel Mech/Electronic Meter 2 INCH STAINLESS STEEL METER ASSY ITEM NO. PART NUMBER DESCRIPTION 68104756 K4561934-10 METER ASSEMBLY COMPLETE 2" STAINLESS STEEL MECH/ELEC 68104199 K4514716 METER DOME PLASTIC FOR 2" METER W/ O-RING MECH/ELEC...
Troubleshooting Problem Cause Correction Water conditioner Electrical service to unit has been Assure permanent electrical service (check circuit breaker, GFCI, fails to regenerate interrupted fuse, plug, pull chain, or switch) Controller is defective Replace controller Power failure Reset time of day Softener delivers By-pass valve is open Close by-pass valve...
Page 40
Push correct system settings in Master Settings System Type Mismatch not match on Network Microcontroller Error Calibration or manufacturing test was Contact your Watts representative not performed 100 Days Without Regen 100 Days have expired without a regeneration Trigger a manual regeneration...
Water Softener Flow Diagrams - Down Flow Brining 1 Service Position 4 Slow Rinse Position 5 Rapid Rinse Position 2 Backwash Position 3 Brine Position 6 Brine Tank Refill Position...
Page 42
Water Softener Flow Diagrams - Up Flow Brining 1 Service Position 4 Backwash Position 2 Brine Position 5 Rapid Rinse Position 3 Slow Rinse Position 6 Brine Tank Fill Position...
AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED IN DURATION TO ONE YEAR FROM THE DATE OF ORIGINAL SHIPMENT. Watts Regulator Co. USA: T: (800) 659-8400 • F: (800) 659-8402 • N. Andover, MA 01845 • Watts.com Canada: T: (888) 208-8927 • F: (905) 481-2316 • Burlington, ON L7L 5H7 • Watts.ca Latin America: T: (52) 55-4122-0138 •...
Need help?
Do you have a question about the HCTA-200-PPSM and is the answer not in the manual?
Questions and answers