Watts HC-300 Manual

Watts HC-300 Manual

3" commercial water softeners

Advertisement

Quick Links

IOM-WQ-HC-300
Installation, Operation and Maintenance
3" Commercial Water Softeners
Series: HC-300, HCTA-300 & HCP-300
HC-300 Simplex Systems
HCTA-300 Duplex Alternating Systems
HCP-300 Duplex, Triplex and Quadplex
Progressive Systems

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HC-300 and is the answer not in the manual?

Questions and answers

Summary of Contents for Watts HC-300

  • Page 1 IOM-WQ-HC-300 Installation, Operation and Maintenance 3" Commercial Water Softeners Series: HC-300, HCTA-300 & HCP-300 HC-300 Simplex Systems HCTA-300 Duplex Alternating Systems HCP-300 Duplex, Triplex and Quadplex Progressive Systems...
  • Page 2 Congratulations on your purchase of this Watts commercial water softening solution. ® You have made a great choice to protect your plumbing system against the damaging effects of hard water. This system has been engineered for trouble free operation and produced using top quality components. Simple programming, corrosion resistant mineral tank(s) and an easy to service design ensures this system will be durable and easy to maintain.
  • Page 3: Safety Information

    If you are unsure about installing your Watts water softener • To disconnect power, unplug the AC adapter from its power contact a Watts representative or consult a professional water source.
  • Page 4: Table Of Contents

    Start Up Instructions ....... .11 lime scale build up in plumbing systems, water spots, and an Installation Diagrams - Series HC-300 Simplex Systems ..12 increase in soap and cleaning product usage.
  • Page 5: Project Data Sheet

    Project Data Sheet Job Details Job Number: _____________________________________________ Model Number/Serial Number: ______________________________ Water Hardness: _______________ppm or gpg Capacity Per Unit: Mineral Tank Size: _____________Diameter: _____________ Height: Salt Setting per Regeneration: Regenerant Flow:_____________Upflow _____________ Downflow 1. Meter Size: A. 3/4" Paddle Wheel B.
  • Page 6: System Specifications

    NOTICE Dimensional data is for a single mineral tank system ONLY. HCP-300 models are composed of multiple HC-300 systems which can be arranged accordingly to suit floor space availability. See Space Required in table below for single tank systems and estimate 2 spaces for duplex, 3 spaces for triplex and 4 spaces for quadplex HCP-300 series systems.
  • Page 7 System Specifications General System Information for 3" Simplex (HC-300) and Duplex Alternating (HCTA-300) Softeners SPACE SHIPPING MODEL NO. ORDERING CODE DESCRIPTION REQUIRED WEIGHT D X W X H M4110B-39NT 68105467 10 Cubic Foot 3" Simplex Softener with Flow Meter 39" X 74" X 103"...
  • Page 8: Set Up

    Hardness (maximum) ... Depends on customer’s series number. If any components are missing or damaged acceptable hardness contact your Watts representative. If they can not be reached leakage level contact Watts customer service at 800-659-8400.
  • Page 9: System Installation

    O-ring applications. 4i. Press the factory suppled stainless steel upper diffuser Watts recommends Ordering Code #68102757 Silicone Lubricant. The use of other types of lubricants may attack basket, flared side up, into the top flange port of the min- the control’s plastic or rubber components.
  • Page 10 1". Install the brine line flow controller(s) (BLFC) 7*. Connect the cold water supply to the inlet port of the water for the HC-300 and HCP-300 series systems directly to the softening system’s control valve(s). When constructing the control valve’s brine connection port(s).
  • Page 11: Start Up Instructions

    System Installation Start Up Instructions brine tank in the system only after the proper brine tank refill time has been programmed into each controller. 1. Ensure all inlet and outlet isolation valves and the bypass 11. Put the appropriate amount of salt in each brine tank. Do Not valves are in the closed position and the treated water faucet fill the salt level past the brine well lid.
  • Page 12: Installation Diagrams - Series Hc-300 Simplex Systems

    6. A GFCI equipt electrical outlet should be provided within 5 feet Drain and Brine Connection Detail for HC-300 & HCP-300 Series of equipment location. Drain water out to drain 7. Use dielectric unions on plumbing connections of control valve when dissimilar metals are present.
  • Page 13: Installation Diagrams - Series Hcta-300 Duplex Alternating Systems

    Installation Diagrams - Series HCTA-300 Duplex Alternating Systems Top View Side View MINERAL TANK POWER CORD (SEE NOTE 13) BRINE TANK (SEE NOTE 14) 1" SCH 40 PVC PIPING (SEE NOTE 15) BRINE LINE FLOW CONTROLLER Drain and Brine Connection Detail for HCTA-300 Series Drain water out to drain Drain Line Flow Control Housing &...
  • Page 14: Installation Diagrams - Series Hcp-300 Progressive 2-4 Tank Systems

    Installation Diagrams - Series HCP-300 Progressive 2-4 Tank Systems Top View Side View MINERAL TANK POWER CORD (SEE NOTE 13) BRINE TANK (SEE NOTE 14) 1" SCH 40 PVC PIPING (SEE NOTE 15) Front View INLET UNION ISOLATION VALVE (SEE NOTE 4) VACUUM RELIEF BYPASS VALVE (SEE NOTE 8)
  • Page 15: Controller Electrical Connections

    Wire Harness Meter Cable Power Supply 44404 Rev A 3150/3900 Valves*: Communication Cables Wire Harness Hinge Mount: mount per valve model noted Meter Cable Power Supply 44403 Rev A *HC-300, HCTA-300 & HCP-300 Systems use 3900 Type Control Valves.
  • Page 16: Wiring Diagram

    Wiring Diagram 44403 Rev A...
  • Page 17: Nxt2 Controller Programming And Operation

    Filter - Identifiable Software Version - Total Number of Regenerations - Regeneration Interval - Last Settings Change - Error Log History - Average Daily Usage (per weekday, 3 month history) *HC-300, HCTA-300 & HCP-300 Systems use 3900 Type Control Valves.
  • Page 18: Controller Display

    Controller Display...
  • Page 19: Controller Operation

    Controller Operation Setting the Time of Day Note: Set Time of Day on any unit and the rest of the units in the system will update the Time of Day automatically. 1. Press and hold the Up button for 2 seconds. The “Time” value is displayed.
  • Page 20: Controller Features

    Controller Features Remote Lock Regeneration Types The controller does not allow the unit/system to go into Softener/Filter Meter Delayed - When volume remaining Regeneration until the Regeneration Lockout Input signal to the reaches zero and the scheduled regeneration time is reached unit is cleared.
  • Page 21 Controller Features Push Settings System 8 (2 Units) Alternating Delayed The ability to transmit user settings from one unit to all other con- Immediate Transfer Delayed Regeneration One tank online sup- nected units. Select the desired Master Programming settings plying treated water, one tank in Standby. Only #1 control will on one unit then push the same settings to all other connected monitor its flow meter/sensor input.
  • Page 22: Master Programming Mode Flow Chart

    5 minutes of inactivity the controller Example: will exit automatically. To exit master programming without 2510, 2750, 2815, 2900, 3150, 3900: HC-300, HCTA-300 & HCP-300 Systems use 3900 Type Control Valves. saving changes, press the Left button until you return to the service screen.
  • Page 23: User Programming Mode Flow Chart

    Paddle (0.75", 1", 1.5", 2", 3") Example: Turbine (0.75", 1.25", 1.5") Generic Range: Off - 99 Days All HC-300, HCTA-300 & HCP-300 use a 3" Paddle Meter. Example: Range: 0.1 to 999.9 gpm/Lpm Example: Range: 0 - 23 Hours 59 Minutes...
  • Page 24: Diagnostic Programming Mode Flow Chart

    Diagnostic Programming Mode Flow Chart Diagnostic Programming Mode Example: 1. Press and hold the Left button to enter Diagnostic Record of error events chronologically Programming mode. 2. To navigate, press the Extra Cycle button to advance to the next value. Press the Left button to retreat to the previous value. Example: 3.
  • Page 25: Time Of Day Programming Mode Flow Chart

    Time of Day Programming Mode Flow Chart Setting the Time of Day NOTE: Set Time of Day on any unit and the rest of the units in the system will update the Time of Day automatically. 1. Press and hold the Up button for 2 seconds. The “Time” value is displayed.
  • Page 26: Nxt2 Programming Parameters And Ranges

    NXT2 Programming Parameters and Ranges SYSTEM TYPE PROGRAMMING PARAMETER RANGES SOFTENER/ SOFTENER/ PROGRESSIVE TIME FILTER FILTER REGEN TYPE OF THE INTERLOCK SERIES ALTERNATING ALTERNATING ALTERNATING DEMAND METRIC CLOCK METERED METERED WEEK RECALL IMMEDIATE DELAYED Settings Review On, Off English Francais Deutsch Language Italiano...
  • Page 27: Replacing The Media

    Replacing the Media 11. Note the top of the distributor tube. It must be flush with the NOTICE top of the tank. If it is above the top of the tank by more than Ion exchange resin may need to be replaced periodically 1/2"...
  • Page 28 Replacing the Media - Cont’d 22. Open the inlet isolation valve slightly, until water can be heard flowing through the isolation valve and allow the mineral tank to fill with water. Air will come out of the drain line until the mineral tank is full of water.
  • Page 29: Replacement Parts - Major System Components

    Replacement Parts - Major System Components MAJOR SYSTEM COMPONENTS ITEM NO. ORDERING CODES DESCRIPTION 68103969 K4041-NTH VALVE 3900/1800 120V HWBP FOR SIMPLEX MODELS 68103966 K4041-NT VALVE 3900/1800 120V NHWBP FOR ALTERNATING & PROGRESSIVE MODELS 68104692 K4560710-2.0 BRINE FLOW CONTROLLER ASSEMBLY 2.0 GPM 1" MXF F/24" SOFTENER 68104693 K4560710-5.0 BRINE FLOW CONTROLLER ASSEMBLY 5.0 GPM 1"...
  • Page 30 C1039 FIBERGLASS MINERAL TANK 42X72 ALMOND W/ 6" TOP & BOTTOM FLANGE 68100712 C1040 FIBERGLASS MINERAL TANK 48X72 ALMOND W/ 6" TOP & BOTTOM FLANGE 68100326 A4000 SOFTENING RESIN MEDIA WATTS BRAND HIGH CAPACITY SAC NA FORM 68100354 A7005A MEDIA GRAVEL #20 FLINT .06"X.125" 68100356 A7006A MEDIA GRAVEL .25"X.125"...
  • Page 31: Replacement Parts - 3900 Upper Powerhead

    Replacement Parts - 3900 Upper Powerhead 3900 UPPER POWERHEAD ITEM NO. PART NUMBER DESCRIPTION 68104640 K4560416-NT UPPER POWERHEAD F/ 3900 24V NTXT2 W/POWER SUPPLY F/120V USA WO/COVER 68104580 K4560240 COVER F/3150 & 3900 UPPER POWERHEAD 68104399 K4519791-02 ELECTRONIC METER CABLE 25' 68104471 K4544164 POWER SUPPLY CABLE 120V/24VDC F/NXT2...
  • Page 32: Replacement Parts - Nxt2 Controller Assembly

    NXT2 Controller Assembly NXT2 CONTROLLER ASSEMBLY ITEM NO. PART NUMBER DESCRIPTION 68104777 K4562115 CONTROLLER ASSEMBLY NXT2...
  • Page 33: Nxt To Nxt2 Conversion Kit

    NXT to NXT2 Conversion Kit NXT TO NXT2 CONVERSION KIT ITEM NO. PART NUMBER DESCRIPTION 68104778 K4562121-01 CONTROLLER ASSY CONV KIT NXT TO NXT2 W/ POWER SUPPLY FOR USA...
  • Page 34: Replacement Parts - 3900 Lower Powerhead

    Replacement Parts - 3900 Lower Powerhead 3900 LOWER POWERHEAD ITEM NO. PART NUMBER DESCRIPTION 68104642 K4560058-03 LOWER POWERHEAD F/ 3900 24V NTXT2 WO/ COVER 68104581 K4560240-22 COVER F/3900 LOWER POWERHEAD...
  • Page 35: Replacement Parts - 3900 Control Valve Body

    Replacement Parts - 3900 Control Valve Body 3900 DOWNFLOW CONTROL VALVE BODY ASSEMBLY ITEM NO. ORDERING CODES DESCRIPTION VALVE BODY 3900 MACHINED, NPT U.S. TAP 68104540 K4560102-00 PISTON ASSEMBLY DOWNFLOW F/3150 & 3900 UPPER 68104560 K4560131 SEAL & SPACER KIT F/3150 & 3900 UPPER 68104542 K4560107-00 PISTON ASSEMBLY DOWNFLOW HWBP F/ 3900 LOWER 68104543...
  • Page 36: Replacement Parts - 1800 Brine Valve

    Replacement Parts - 1800 Brine Valve 1800 BRINE VALVE ASSEMBLY ITEM NO. PART NUMBER DESCRIPTION 68104501 K4560036-02 BRINE VALVE ASSEMBLY 1800 BRASS DESIGN #3 68104582 K4560276-01 BRINE VALVE ASSEMBLY 1800 BRASS RETROFIT KIT TO UPDATE TO DESIGN #3...
  • Page 37: Replacement Parts - 1800 Injector Assembly

    Replacement Parts - 1800 Injector Assembly 1800 INJECTOR ASSEMBLY ITEM NO. PART NUMBER DESCRIPTION 68104583 K4560277-05 INJECTOR ASSEMBLY 1800 W/#5 INJECTOR 68104584 K4560277-07 INJECTOR ASSEMBLY 1800 W/#7 INJECTOR 68104585 K4560277-08 INJECTOR ASSEMBLY 1800 W/#8 INJECTOR 68104244 K4515128-04 INJECTOR NOZZLE 1800 #4 GREEN 68104245 K4515128-05 INJECTOR NOZZLE 1800 #5 RED 68104246...
  • Page 38: Replacement Parts - 3" Stainless Steel Electronic Meter

    Replacement Parts - 3" Stainless Steel Mech/Electronic Meter 3 INCH STAINLESS STEEL METER ASSY ITEM NO. PART NUMBER DESCRIPTION 68104758 K4561935-10 METER ASSEMBLY 3" STAINLESS STEEL ELECTRONIC/MECHANICAL 68110068 K4561939 METER DOME MECH/ELEC STANDARD RANGE FOR .75"-3" METER W/ O-RING...
  • Page 39: Troubleshooting

    Troubleshooting Problem Cause Correction Water conditioner Electrical service to unit has been Assure permanent electrical service (check circuit breaker, GFCI, fails to regenerate interrupted fuse, plug, pull chain, or switch) Controller is defective Replace controller Power failure Reset time of day Softener delivers By-pass valve is open Close by-pass valve...
  • Page 40 Push correct system settings in Master Settings System Type Mismatch not match on Network Microcontroller Error Calibration or manufacturing test was Contact your Watts representative not performed 100 Days Without Regen 100 Days have expired without a regeneration Trigger a manual regeneration...
  • Page 41: Water Softener Flow Diagrams

    Water Softener Flow Diagrams - Down Flow Brining 1 Service Position 3 Brine Position Service Outlet Inlet Drain Drain Regeneration Valve Inlet Service Inlet Valve Hard water enters at valve inlet – flows thru injector nozzle and Hard water enters at valve inlet and flows down thru mineral to throat to draw brine from the brine tank.
  • Page 42 Water Softener Flow Diagrams - Down Flow Brining 5 Rapid Rinse Position 6 Brine Tank Refill Position Service Outlet Inlet Drain Drain Inlet Inlet Hard water enters at valve inlet – flows thru the regeneration valve directly down thru the mineral – into the bottom distributor Hard water enters at valve inlet –...
  • Page 43: Flow Data And Injector Draw Rates - Down Flow

    Flow Data and Injector Draw Rates - Down Flow 3900 Valve & 3" Dist. Tube on 24" Tank 3900 on Empty Tank...
  • Page 44: Injector Nozzle And Throat Chart For 1800 Brine Systems

    AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED IN DURATION TO ONE YEAR FROM THE DATE OF ORIGINAL SHIPMENT. Watts Regulator Co. USA: T: (800) 659-8400 • F: (800) 659-8402 • N. Andover, MA 01845 • Watts.com Canada: T: (888) 208-8927 • F: (905) 481-2316 • Burlington, ON L7L 5H7 • Watts.ca Latin America: T: (52) 55-4122-0138 •...

This manual is also suitable for:

Hcta-300Hcp-300

Table of Contents