3. Remove the front grille.
a. At bottom right side of the front grille, press inward on
cabinet near the power cord, and pull the grille outward
to the right until right tabs releases.
b. At the bottom left side, push inward on cabinet and pull
the grille outward to the left to release the left tab.
c. Slide the front grille upwards to free the two top tabs at
the top of the cabinet.
11.14. How to attach the Drain Pan
(Optional)
Condensed water drainage.
This air condtioner employs a "Singer -Up System" which is
designed to splash he condensed water on the condensed coil
for maximum cooling efficiency, thus producing a splashing
sound. If the splashing sound annoys you, you can provide an
outside drainage by using the following procedure which may,
however, cause a small loss of performance.
NOTE: The cabinet should be installed tilted slightly lower to
the rear for necessary condensate drainage. (Max. 13/32")
1. Remove the rubber plug and slide the chassis out from the
cabinet
2. Install the optional drain pan (part no. CWH40175). Install
the drain pan at the right corner of the cabinet using 2
screws (part no. CWG86C3733).
Note: The drain pan (part no. CWH40175) can be obtained
from nearest servicentre.
3. Connect a drain hose (optional).
Fit the drain hose to the drain pan.
Note: Drain hose or tubing can be purchased locally to
satisfy your particular needs.
4. Slide the chassis back into the cabinet.
Reinstall the cabinet screws.
Secure the cabinet to chassis by using screws.