Humidified Models - Hatco Glo-Ray GRCD-1P Installation & Operating Manual

Grcd & grhd series heated display cases
Hide thumbs Also See for Glo-Ray GRCD-1P:
Table of Contents

Advertisement

HUMIDIFIED MODELS

1. Plug cabinet into a properly grounded electrical
outlet of the correct voltage, size and plug
configuration. See Specifications for details.
2. Remove the center slotted pan divider from
the water trough.
3. Turn the Power Switch to the ON position. See
Figure 12.
4. Rotate the Humidity Selector Control to the desired
position. The green Humidity On Indicator will light
up to show that humidity is on. The red Low Water
Indicator will light when the water trough is empty.
5. Fill the water trough with softened or distilled water.
The trough has a 3 quart (2.8 liter) capacity.
If the red Low Water Indicator is on, press
the Reset Button.
NOTE: Use of softened or distilled water
is recommended to preserve the life of electrical
and mechanical components. If hard water is used,
the trough will require periodic cleaning and deliming.
See Maintenance section for deliming instructions.
6. Re-install the center Pan Divider.
7. On start-up set all heat controls at maximum
to assure safe food holding.
On dual tier models, the Top and Center
Heat Indicators will light when controls
are in the ON position.
Humidity Selector Control
Top & Center Heat Indicators*
Reset
Button
Power Switch
Low Water
Indicator
Humidity On
Indicator
*Dual tier models only.
Figure 12. Control Panel – Humidified Models
NOTE: Temperature and humidity settings may vary
depending upon product make-up and consistency.
NOTE: The trough capacity permits uninterrupted
operation for approximately 4 hours, depending
on the settings and how frequently the door is opened.
When the red Low Water Indicator lamp is lit, add water
to the reservoir and press the Reset Button.
8. Allow unit 30 minutes to reach operating
temperature.
9. At the end of the day or shift, turn unit
off and allow to cool down. Remove and clean
the water trough.
15
OPERATION
Center Heat Control*
HATCO GLO-RAY
ON
OFF
Top Heat Control
Base Heat Control
Form No. GRCD/HDM-0703

Advertisement

Table of Contents
loading