1.
Weekday
2.
Open window Sign
3.
Timer Sign
4.
WiFi Sign
5.
Time
6.
Temperature
4.3 Screen display:
4.4 Open window detection:
This heater is equipped with an open window detection function. If our control system detects that the room
temperature decreases dramatically in short period when the heater is in the heating status, it will
recognize that a window is open. The window sign on the screen will start to flash and the heater will power
off for 30 minutes and get back to the previous setting automatically after 30 minutes.
You can deactivate and activate this function by long pressing for 5 seconds the "-" button, and the open
window sign on the screen will disappear and appear accordingly.
4.5 Temperature calibration
Long press "+" button for 5 seconds to enter the temperature calibration, adjust the number by pressing "-"
or "+" button, the calibration ranges from -5 to +5 degrees.
4.6 WiFi function on/off
Long press "Timer" button for 10 seconds to disable the WiFi connection and the WiFi sign on the screen
will disappear, long press "Timer" button for 10 seconds to turn it on again.
4.7 Manual control:
To enter the manual mode, activate the power switch, press power button to power on the heater and the
"M" sign will show on the screen. Now the heater operates in the manual mode, adjust your desired
temperature by pressing "-" or "+" button, 2 seconds later the screen will retain to the reading of current
room temperature.
If you would like to set up the timer, press timer button and "00H" will appear on the screen and you can set
the timer by press "-" and "+" button to start the count-down timer.