Use the following procedure to add a PC to a new or existing project.
1. Select the project from the project tree, and either select Edit/New PC or
right-click and select New PC from the pop-up menu.
2. Enter the Device Name. New PC @ (where @ = 1, 2 etc.) is the default
name.
3. Set the PC Device Type by clicking on the PC Device Type drop-down list
and selecting the device type.
4. Set the Network Address, Node Address, and Unit No. under Network Type
for the applicable PC on the FINS network.
Before making the above settings, however, the FinsGateway settings
must be made. Match the Network Type settings to the FinsGateway set-
tings.
Use the following settings when connecting using Host Link (SYSWAY-CV)
and the default FinsGateway Serial Unit driver settings:
• Network Address: 0
• Node Address:
• Unit No.:
Refer to 6-2 FinsGateway Configuration and Startup for information on
FinsGateway settings.
Note When connecting using Host Link (SYSWAY-CV), the FinsGateway
Serial Unit driver node number setting shown in the following window
must match the Node Address set under the Network Type. The
Node Address must be set to 240 to enable going online. Even if the
protocol is correctly set to SYSWAY-CV, online access will not be
possible with any other address because the FinsGateway Serial
Unit driver default node number setting (shown in the following win-
dow) is 240. If CX-Position online operations are started with any oth-
240 (default setting is 240, not 0)
0 (fixed setting)