Tubing Connections - Nimbus Water Systems CS-3 Manual

Reverse osmosis system
Table of Contents

Advertisement

CS-3 Tubing Connecti ons
1. Measure and cut a length of tubing 1/4" tubing long enough to reach from the faucet to the faucet connector on the
system. Connect one end to the faucet nipple using a jaco nut and plasti c insert. Connect the other end to the faucet con-
necti on on the post-fi lter suing a jaco nut and plasti c insert.
2. Measure and cut the length of 1/4" tubing long enough to reach from the feed water supply to the inlet. Connect the
end to the feed inlet on the prefi lter using a jaco nut and plasti c insert. See Fig. 5.
3. Connect one end of a 3/8" length of tubing to the tank valve. Insert the other end fi rmly into the quick-connect cross on
the shut-off valve.
4. Connect the 1/4" tubing from the faucet to the white swivel with yellow collet on the membrane desalinator.
5. Connect the free end of the 3/8" drain tubing to the drain connecti on.
COMPRESSION NUT
INSERT
TUBING
FERRULE
Fig. 5
41840-A McAlby Court, Murrieta, CA 92562
7
(800) 451-9343, www.nimbuswater.com