Functionality - AVT MAGIC EEC Hardware Manual

Eti/edi converter
Hide thumbs Also See for MAGIC EEC:
Table of Contents

Advertisement

1.5

Functionality

MAGIC EEC is equipped with a G.703/G.704 input/output (for ETI signal) and two
LAN interfaces which can be configured freely regarding their functionality
(input/output for EDI signal, control and configuration, SNMP). A second ETI
module can be equipped, whereby an additional and unrestricted ETI output is
available. This may be used as a monitoring output or to supply a redundant
ensemble multiplexer, for example.
Configuration and control are especially comfortable with the MAGIC EEC Windows
PC software which is included in delivery and which communicates with the system
via the LAN interface.
For an external alarm signalling eight TTL contacts and eight relays are provided. All
alarm or status events are also stored in an internal system logfile, which is
readable via the logfile browser of the PC software. Alternatively, an automatic
download in e.g. a network folder is possible.
Via the integrated SNMP agent, which supports the SNMP v1/v2 protocols, control
of the system can be realised for up to four independent network management
systems.
With the optional SDC upgrade a MAGIC EEC system can be upgraded to a full
MAGIC SDC Switch & Converter.
Options
Monitoring output
A second ETI module can be optionally equipped, which means that an
additional unrestricted ETI output is available. This can be used, for
example, as a monitoring output or to supply a redundant Ensemble
Multiplexer.
SDC Upgrade
The optional SDC upgrade allows a MAGIC EEC system to be upgraded to a
full-featured MAGIC SDC Switch & Converter.
Dual converter mode
With this upgrade MAGIC EEC has two independent ETI/EDI converters.
For the Dual Converter mode you need a MAGIC EEC with monitoring
output (second ETI module).
Dual LAN Upgrade
Optional extension with two additional Ethernet interfaces. The
assignment of functions such as EDI, SNMP etc. is freely configurable.
However, a second EDI module can then no longer be assembled.
Redundant Power Supply
Optionally a redundant power supply can be used, the 5V DC table power
supply is included in this hardware upgrade.
N+1 Redundancy Upgrade
The N+1 redundancy upgrade adds an additional EDI input to the system
to enable non-seamless redundancy switching in the event of errors in the
EDI input signal of the main path. This option provides a cost-effective N+1
redundancy solution using our MAGIC DABMUX Go or MAGIC DABMUX
plus in an N+1 multiplex setup. This feature is only available in EDI → ETI
conversion mode.