Atlas Copco XAS 185 CD7 T4F HOP Instruction Manual page 35

Engine c2.2t
Table of Contents

Advertisement

The engine will now run at maximum rpm, the display will
show
The loading valve will be energized and pressure starts
building up.
Active Buttons
Stop Button
(to cancel Start command)
Load Button
(to cancel Load command)
Measurement View Button
Settings View Button
Alarms View Button
During loading the following display is shown (default
display)
The controller controls the speed of the engine in order to
meet the requested working pressure, at the most
economical fuel usage.
Active Buttons
Stop Button
(to cancel Start command)
Load Button
(to cancel Load command)
Measurement View Button
Settings View Button
Alarms View Button
- 35 -
During operation
The doors must be closed during operation
and may be opened for short periods for
inspection and adjustments only.
Be aware not to touch hot or moving parts
when the door is open.
When the engine is running, the air outlet
valves (ball valves) must always be put in a
fully opened or fully closed position.
Regularly carry out following checks:
1.
Ensure that the regulating valve (RV) is correctly
adjusted, i.e. starts decreasing the engine speed when
reaching the preset working pressure in the receiver.
2.
Check the air outlet temperature of the compressor
element.
3.
Check the engine oil pressure, the coolant tempera-
ture and display of control box.
4.
Avoid the engine running out of fuel. Nevertheless, if
this happens, fill the fuel tank and prime the fuel sys-
tem to speed up starting.