EH SERIES USER MANUAL
HYBRID INVERTER

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GW-GW5000-EH and is the answer not in the manual?

Questions and answers

Summary of Contents for Goodwe GW-GW5000-EH

  • Page 1 Official Website APP (iOS) APP (Android) EH SERIES USER MANUAL HYBRID INVERTER...
  • Page 2: Table Of Contents

    INTRODUCTION 1.1 OPERATION MODES INTRODUCTION 1.2 SAFETY & WARNINGS 1.3 PRODUCT OVERVIEW INSTALLATION INSTRUCTIONS 2.1 UNACCEPTABLE INSTALLATIONS 2.2 PACKING LIST 2.3 MOUNTING 2.3.1 SELECT MOUNTING LOCATION 2.3.2 MOUNTING 2.4 ELECTRICAL WIRING CONNECTION 2.4.1 PV CONNECTION 2.4.2 BATTERY CONNECTION 2.4.3 ON-GRID & BACK-UP CONNECTION 2.4.4 SMARTMETER &...
  • Page 3 GoodWe EH series, also called hybrid or bidirecational solar inverters, apply to solar system with participa- as GoodWe) strictly comply with related safety rules for product design and testing. Please read and follow tion of PV, battery, loads and grid system for energy management. The energy produced by PV system...
  • Page 4: Product Overview

    The temperature of inverter surface might exceed 60℃ during working, so please make sure it is cooled down before touching it, and make sure the inverter is untouchable for children Do not open inverter cover or change any components without GoodWe’s authorization, otherwise the warranty commitment for the inverter will be invalid.
  • Page 5: Installation Instructions

    INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS 2.3 MOUNTING INSTALLATION INSTRUCTIONS 2.3.1 SELECT MOUNTING LOCATION For inverter’s protection and convenient maintenance, mounting location for inverter should be selected 2.1 UNACCEPTABLE INSTALLATIONS carefully based on the following rules: Any part of this system shouldn’t block the switch and breaker to disconnected inverter from DC and AC power. Rule 1.
  • Page 6: Mounting

    INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS 2.4 ELECTRICAL WIRING CONNECTION 2.3.2 MOUNTING 2.4.1 PV WIRING CONNECTION Remember that this inverter is heavy! Please be careful when lifting out from the package. The inverter is suitable for mounting on concrete or other non-combustible surface only 19.33 Step 1 Wall bracket...
  • Page 7: Battery Connection

    Besides, do not remove the battery plug and save the battery Below are the requirements of On-Grid AC breaker. terminals, if lost, contact GOODWE for sale. Please be careful against any electric shock or chemical hazard.
  • Page 8 Special Adjustable Setting The inverter has filed adjustable setting like tripping point, tripping time, reconnect time, active and invalid of QU/PU curves etc. by special firmware. Please contact GoodWe after sales for the special firmware and adjust methods. Connection For SPLIT Grid System...
  • Page 9: Smartmeter & Ct Connection

    If you buy a Battery-Ready inverter without the Smart Meter, it is not necessary to view this section. The Smart Meter with CT in GoodWe product box is compulsory for EH system installation, used to detect grid voltage and current direction and magnitude, further to instruct the operation condition of EH inverter via RS485 communication.
  • Page 10: Earth Fault Connection

    (Pic 32). 2.6 EARTH FAULT ALARM CONNECTION GoodWe EH series inverter complies with IEC 62109-2 13.9. Fault indicator LED on inverter cover will light up and the system will email the fault information to customer. Inverter should be installed at eye level for convenient maintenance.
  • Page 11: Wifi Configuration

    Note: After the inverter is installedand worked normal when the grid connected , please turn off the then to solid status, which means Wi-Fi is connected to GoodWe icloud successfully. grid power to check whether the back-up function is normal, which can avoid the problems in 3.
  • Page 12: Pv Master App Operation

    PV Auto-Test function of CEI is integrated in PV Master APP for Italy safety country requirement. For GoodWe will keep right to explain all the contents in this user manual. To insure IP65, inverter must be sealed well, please install the inverters in one day after unpacking, otherwise please...
  • Page 13: Error Message And Troubleshooting

    3. Check the resistance betwen PV1+/PV2+/BAT+/PV- to earth, if the resistance is lower than 33.3k, check the system wiring connection. 4. Try to restart the inverter, check if the fault is still happens, if not, means it is just an occasional situation, or contact GoodWe.
  • Page 14 OTHERS OTHERS Possible Problems During Operation EH and Smart meter is OK or not; 100W 100W 100W (L/N are in sequence) (20%+1-DOD) / 2 Smart Inverter Smart Meter Note: For compatible lithium batteries, BMS status is "Communication OK" after selecting the right battery type.
  • Page 15: Technical Parameters And Certificates

    OTHERS OTHERS 4.4 TECHNICAL PARAMETERS AND CERTIFICATES • TECHNICAL PARAMETERS OF HYBRID CONVERTERS Off-Grid Output Switch Off-Grid Output Switch A:For EH series inverter, it could connect Lithium batteries which have compatibility with EH series inverter. With nominal voltage from 85V to 450V. Compatible lithium batteries can see on battery list in PV MASTER APP...
  • Page 16 OTHERS OTHERS 4.3 TECHNICAL PARAMETERS AND CERTIFICATES Technical Data GW6000-EH GW5000-EH GW3600-EH TECHNICAL PARAMETERS OF EH INVERTER Back-up Output Data (UPS) Nominal Ouput Frequency (Hz)(@Linear Load) 50/60 (±0.2%) Technical Data GW6000-EH GW5000-EH GW3600-EH Output inrush Current (peak/duration) 65A, 5µs Battery Input Data Maximum output RMS overcurrent protection (A) Battery Type Li-Ion...
  • Page 17 OTHERS OTHERS 4.4 WARNING QUICK CHECK LIST Technical Data GW6000-EH GW5000-EH GW3600-EH Certifications & Standards [1] Inverter cannot be installed near flammable, explosive or strong electro-magnetic equipment, page Nominal Ouput Frequency (Hz) AS/NZS 4777.2:2015; G99/1; CEI 0-21 (@Linear Load) VDE4105-AR-N [2] Remember that this inverter is heavy! Please be careful when lifting out from the package, page 07 Safety Regulation IEC/EN62109-1&2...
  • Page 18: Checking The Electrical Connection

    OTHERS 4.5 CHECKING THE ELECTRICAL CONNECTION 1. Check if the AC or DC wire is loose. 2. Check if the earth wire is reliable grounding. 3. Check if the waterproof covers of BMS and Meter port is fasten. 4. Please use torque wrench to tighten the AC and battery terminal wiring connection once a year;...