4.2 Installation procedure

1. Align the hole template (locating plate) with the ground and stick it flat on the wall.
2. Align the hole template on the installation surface and drill holes with a diameter of
8mm and a depth of 40mm on the wall.
3. Install the m6x60 expansion screws into the previously drilled holes.
4. Secure fixing bracket to the wall using a socket wrench and tighten the expansion screws.
5. Align the unit with the fixing bracket on the wall and lift the unit on to the bracket by
lowering it into the holes.
6. Prepare the unit for installation of cabling
1
Locating Plate
5

4.3 Earth Connection

A secondary protection grounding terminal can be found on the system. Ensure that the
grounding resistance is less than 10 Ω and the grounding cable diameter is not greater than
10mm2.
Rev 20220610
2
Locating Plate
Figure 4-2 - Battery unit mounting steps