1.7 Setup

The following two system configurations for the IE-703002-MC are possible, depending on the purpose.
This section describes the setup procedure according to each purpose as follows.

1.7.1 When using IE-703002-MC on stand-alone basis for performing software debugging

(1)
Connect interface board to PC
Before connecting, make sure that the power of the PC is off.
(2)
Set clock operation mode of IE-703002-MC
The IE-703002-MC is provided with a 6.667 MHz crystal oscillator when shipped from the factory.
The clock setting differs depending on the option board used.
For details, refer to the user's manual of the option board used.
(3)
Set illegal access detection ROM
Switch the illegal access detection ROM.
(For details, refer to the user's manual of the option board used.)
(4)
Set jumpers to adapt to voltage range of CPU
and target system
Set jumpers to adapt to voltage range of CPU and target system
(For details, refer to the user's manual of the option board used.)
(5)
Connect cables
Connect power source adapter and interface cable.
(6)
Power up IE-703002-MC, then PC
CHAPTER 1 OVERVIEW
Step
Reference section
3.1 Connection to Personal Computer
2.2 Clock Setting
2.3 Setting of Illegal Access Detection ROM
2.4 Operating Voltage Setting
3.3 Cable Connections
3.4 System Power-on and Power-off
User's Manual U11595EJ5V0UM