Risk Of Injury! Always disconnect the blower from the power source
WARNING
before maintenance.

ELECTRICAL SYSTEM

Check the power cable regularly for damage.
If the power cable is damaged, it must be
replaced by qualified person or a service agent.
AIR OUTLETS
dust and other dirt that can collect in the air
outlet must be cleaned and removed regularly.
HOUSINg
Clean the housing with a mild detergent and water.
Problem
Motor does not run
Motor runs, but wheel
spins irregularly or hits
sides.
device vibrates
excessively
© 2016, Pinnacle Climate Technologies, Inc.
668 Stony Hill Road #302 Yardley, PA 19067

Maintenance

Troubleshooting guide

Possible Cause
1. No power supply to the device.
2. Switch / knob not turned on.
3. Fan wheel blocked.
4. air inlet or outlet is blocked.
5. Switch is broken.
6. Loose wiring.
1. a heavy impact has bent the
motor suspension so that the
wheel is stuck.
2. a heavy impact has let
the motor slide out of the
suspension so that the wheel is
stuck.
1. Fan wheel is stuck.
2. Fan wheel is unbalanced.
3. Fan wheel is bent.
4. Motor Shaft is bent.
EXTERNAL PARTS
Check all external parts to ensure they have been
installed properly. be alert for unusual noises.
KEEP MOTOR AND WIRINg DRY
do Not use a water hose or any pressurized
washing device to clean your blower. If any
electrical elements do get wet, they must be dried
immediately.
1. Connect device, check fuse.
2. turn knob on / press power
switch to oN.
3. Inspect fan wheel and remove
blockage.
4. remove blockage and clean air
inlet and air outlet.
5. return to service agent.
6. return to service agent.
1. return to service agent.
2. return to service agent.
1. Clean fan wheel.
2. return to service agent.
3. return to service agent.
4. return to service agent.
6