Plug Replacement - Stanley ST-700-DR-E Instruction Manual

Industrial fan blower
Table of Contents

Advertisement

WARNING
RISK OF ELECTRIC SHOCK! DISCONNECT FROM POWER BEFORE MAINTENANCE.
NOTE: This section only applies to blowers sold or used in Great Britain.
this appliance is supplied with a bS1363 3 pin
plug fitted with a fuse. Should the fuse require
replacement, it must be replaced with a fuse
with the proper amp rating. (see technical
Specifications page 2) and approved to BS1362.
In the event the mains plug has to be removed/
replaced for any reason, please note:
IMPORTANT: the wires in the mains lead are
colored in accordance with the following code:
blue – Neutral
Green/Yellow – Earth
as the colors of the wires in the mains lead of this
appliance may not correspond with the colored
markings identifying the terminals in your plug,
proceed as follows:
Figure 4
© 2016, Pinnacle Climate Technologies, Inc.
668 Stony Hill Road #302 Yardley, PA 19067

Plug Replacement

brown – Live
Plug Replacement Wiring Diagram
BLUE
Neutral
CORD CLAMP
the blue wire must be connected to the terminal
marked with an N or colored black. the brown
wire must be connected to the terminal marked
with an L or colored red. the green/ yellow wire
must be connected to the earthing terminal which
is marked with an E or with the earth symbol.
WARNING
the plug.
NOTE: If a moulded plug is fitted and has to
be removed take great care in disposing of the
plug and severed cable, it must be destroyed to
prevent engaging into a socket.
GREEN / YELLOW
Earth
5
Never connect live or neutral
wires to the earth terminal of
BROWN
Live
FUSE
13 Amps