Flow-Entry Max-Limit; Flow-Table - H3C S7500E-XS Series Command Reference Manual

Hide thumbs Also See for S7500E-XS Series:
Table of Contents

Advertisement

Default
The connection interruption mode is secure after an OpenFlow instance is activated, and the
controller deploys the table-miss flow entry (the action is Drop) to the OpenFlow instance.
Views
OpenFlow instance view
Predefined user roles
network-admin
Parameters
secure: Configures the OpenFlow switch to use flow tables for traffic forwarding after it is
disconnected from all controllers.
standalone: Configures the OpenFlow switch to use the normal forwarding process after it is
disconnected from all controllers.
Examples
# Set the connection interruption mode to standalone for OpenFlow instance 1.
<Sysname> system-view
[Sysname] openflow instance 1
[Sysname-of-inst-1] fail-open mode standalone

flow-entry max-limit

Use flow-entry max-limit to set the maximum number of entries for the extensibility flow table on an
OpenFlow switch.
Use undo flow-entry max-limit to restore the default.
Syntax
flow-entry max-limit limit-value
undo flow-entry max-limit
Default
The extensibility flow table has a maximum of 65535 flow entries.
Views
OpenFlow instance view
Predefined user roles
network-admin
Parameters
limit-value: Specifies the maximum number of flow entries, in the range of 1 to 65535.
Examples
# Configure the extensibility flow table to have a maximum of 256 entries on OpenFlow instance 1.
<Sysname> system-view
[Sysname] openflow instance 1
[Sysname-of-inst-1] flow-entry max-limit 256

flow-table

Use flow-table to create a flow table for an OpenFlow instance.
22

Advertisement

Table of Contents
loading