Examples
# Display brief OpenFlow instance information.
<Sysname> display openflow summary
Fail-Open mode: Se -- secure mode, Sa -- standalone mode
ID
Status
1
Active
10
Inactive
4094
Active
Table 9 Command output
Field
ID
Status
Datapath-ID
Channel
Table-num
Port-num
Reactivate
fail-open mode
Use fail-open mode to set the connection interruption mode for an OpenFlow switch.
Use undo fail-open mode to restore the default.
Syntax
fail-open mode { secure | standalone }
undo fail-open mode
Datapath-ID
0x0000000100001221
-
0x00000ffe00001221
Description
ID of the OpenFlow instance.
Activation status of the OpenFlow instance:
•
Active—The OpenFlow instance has been activated.
•
Inactive—The OpenFlow instance has not been activated.
Datapath ID of the OpenFlow instance.
If the OpenFlow instance is not activated, this field displays a hyphen (-).
Status of the connection channel to the controller:
•
Connected—A secure channel has been established.
•
Failed(Se)—The connection channel is disconnected from the controller,
and the OpenFlow instance is in secure mode.
•
Failed(Sa)—The connection channel is disconnected from the controller,
and the OpenFlow instance is in standalone mode.
If the OpenFlow instance is not activated, this field displays a hyphen (-).
Number of flow tables included in the OpenFlow instance.
If the OpenFlow instance is not activated, this field displays a hyphen (-).
Number of ports included in the OpenFlow instance.
If the OpenFlow instance is not activated, this field displays a hyphen (-).
Whether the configuration for an OpenFlow instance is changed and whether
the OpenFlow instance needs to be reactivated:
•
Y—The configuration is changed, and the OpenFlow instance needs to
be reactivated.
•
N—The configuration is unchanged, and the OpenFlow instance does
not need to be reactivated.
Channel
Table-num
Connected
2
-
-
Failed(Sa) 2
21
Port-num
Reactivate
8
Y
-
-
0
N