Fail-Open Mode - H3C S7500E-XS Series Command Reference Manual

Hide thumbs Also See for S7500E-XS Series:
Table of Contents

Advertisement

Predefined user roles
network-admin
network-operator
Examples
# Display brief OpenFlow instance information.
<Sysname> display openflow summary
Fail-Open mode: Se -- secure mode, Sa -- standalone mode
ID
Status
1
Active
10
Inactive
4094
Active
Table 9 Command output
Field
ID
Status
Datapath-ID
Channel
Table-num
Port-num
Reactivate

fail-open mode

Use fail-open mode to set the connection interruption mode for an OpenFlow switch.
Use undo fail-open mode to restore the default.
Syntax
fail-open mode { secure | standalone }
undo fail-open mode
Datapath-ID
0x0000000100001221
-
0x00000ffe00001221
Description
ID of the OpenFlow instance.
Activation status of the OpenFlow instance:
Active—The OpenFlow instance has been activated.
Inactive—The OpenFlow instance has not been activated.
Datapath ID of the OpenFlow instance.
If the OpenFlow instance is not activated, this field displays a hyphen (-).
Status of the connection channel to the controller:
Connected—A secure channel has been established.
Failed(Se)—The connection channel is disconnected from the controller,
and the OpenFlow instance is in secure mode.
Failed(Sa)—The connection channel is disconnected from the controller,
and the OpenFlow instance is in standalone mode.
If the OpenFlow instance is not activated, this field displays a hyphen (-).
Number of flow tables included in the OpenFlow instance.
If the OpenFlow instance is not activated, this field displays a hyphen (-).
Number of ports included in the OpenFlow instance.
If the OpenFlow instance is not activated, this field displays a hyphen (-).
Whether the configuration for an OpenFlow instance is changed and whether
the OpenFlow instance needs to be reactivated:
Y—The configuration is changed, and the OpenFlow instance needs to
be reactivated.
N—The configuration is unchanged, and the OpenFlow instance does
not need to be reactivated.
Channel
Table-num
Connected
2
-
-
Failed(Sa) 2
21
Port-num
Reactivate
8
Y
-
-
0
N

Advertisement

Table of Contents
loading