Compressor Mounting; Service Air Connection(S) - Doosan XHP1000WCAT-T4i Operation And Maintenance Manual

Table of Contents

Advertisement

Operating Instructions

Compressor Mounting

Portable compressors, which are modified to remove the running gear and mount the
compressor directly to trailers, truck beds, or frames, etc. may experience failure of the
enclosure, frame, and/or other components. It is necessary to isolate the compressor package
from the carrier base with a flexible mounting system. Such a system must also prevent
detachment of the package from the carrier base in the event the isolators fail. Contact your
Portable Power representative for flexible mounting kits.
Warranty does not cover failures attributable to mounting of the compressor package to the
carrier base unless it is a Portable Power provided system.

Service Air Connection(s)

All air pressure equipment installed, in or connected to, the compressor
must have safe working pressure ratings of at least the safety valve
setting and materials compatible with the compressor oil (Refer to the
General Data).
Do not connect the air discharge on this compressor onto a common
header with any other unit of any description, or any other source of
compressed air, without first making sure a check valve is used between
the header and the compressor. If this compressor is connected in
parallel with another compressor of higher discharge pressure and
capacity, a safety hazard could occur in a backflow condition.
Unrestricted air flow from a hose will result in a whipping motion of the
hose which can cause serious injury or death. A safety device must be
attached to the hose at the source of supply to reduce pressure in case
of hose failure or other sudden pressure release. Reference: OSHA
Regulation 29 CFR Section 1926.302 (b).
WARNING
!
WARNING
!
WARNING
!
Operating & Maintenance Manual