IMPORTANT REMARKS

TO REDUCE THE RISK OF SEVERE INJURY OR DEATH READ THE FOLLOWING REMARKS
CAREFULLY bEFORE PROCEEDING WITH THE INSTALLATION. PAY PARTICULAR ATTENTION
TO ALL THE PARAGRAPHS MARKED WITH THE SYMbOL
INSTRUCTIONS COULD COMPROMISE THE CORRECT WORKING ORDER OF THE SYSTEM.
• These instructions are aimed at professionally qualified "INSTALLERS
OF ELECTRICAL EQUIPMENT" and must respect the local standards
and regulations in force. All materials used must be approved and
must suit the environment in which the installation is situated.
• All maintenance operations must be carried out by professionally
qualified technicians.
• This appliance must be used exclusively for the purpose for which
it has been made. "i.e. for the automation of sliding gates" with
weights of up to 400 kg and a maximum travel distance of 12 m.
• The geared motor can be positioned either to the left or to the right
of the passageway.
Any non authorised modifications are to be considered improper and
therefore dangerous.
Caution! The installation of both anti-derailment
buffers is absolutely obligatory.
IMPORTANT SAFETY INSTRUCTIONS
It is the responsibility of the installer to make sure that the following
public safety conditions are satisfied:
1) Ensure that the gate operating installation is far enough away from
the main road to eliminate possible traffic disruptions and that the
size of the gate, the distance from the road and the work cycle speed
can in no way interfere, causing possible traffic hazards.
2) The motor must be installed on the inside of the property and not on
the public side of the gate. The gates must not open onto a public
area.
3) The gate operator is designed for use on gates through which vehicles
are passing. Pedestrians should use a separate entrance.
4) The minimum controls which may be installed are OPEN-STOP-
CLOSE, these controls must be installed at a height between 1,5 and
1,8 m an in a location not accessible to children. Controls installed
externally must be protected by a safety device inhibiting unauthor-
ised use.
5) The gate must be in full view when it is operating therefore controls
must be situated in a position where the operator can see the gate
at all times.
6) At least two warning signs (similar to the example
on the right) should be placed, where they can be
easily seen by the public, in the area of the system
of automatic operation. One inside the property and
one on the public side of the installation. These signs
must be indelible and not hidden by any objects (such
as tree branches, decorative fencing etc.). Make sure
that the end-user is aware that children and/or pets
must not be allowed to play within the area of a gate
installation. If possible include this in the warning signs
7) A correct earth connection is fundamental in order to guarantee the
electrical safety of the machine
8) Before carrying out any cleaning or maintenance operations make
sure the power is disconnected at the mains, the motor power cables
are disconnected and the batteries have been disconnected.
9) If you have any questions about the safety of the gate operating
system, do not install the operator. Contact your dealer for assist-
ance.
• In order to respect the requirements of the standard EN 12453
(dynamic impact force limitation) make sure the current sensor is
set to SNS1.
Attention! If you use a rubber safety edge (at least 3 cm high)
this is obligatory in order to conform to the standard. If you
can't respect the limits, increase the size of the safety edge
or change the type of edge used.
• You are still obliged to check the impact force using the relative
instrument.
TECHNICAL DESCRIPTION
• Mains power supply 230 Vac.
• Motor powered with a maximum voltage of 38 Vdc.
• A two-piece shell made of die cast aluminium enclosing the reduc-
tion unit and a pair of steel gears, lubricated with permanently fluid
grease.
IMPORTANT REMARKS
• The reduction unit stator is made of die cast aluminium and contains
worm gear and a helicoidal crown wheel made of thermoplastic
lubricated with permanently fluid grease.
• The incorporated electronic programmer contains the power stage,
the logic control and the radio receiver decoding module. The power
supply is routed to the electronics card via a separate transformer
which is housed in the same container.
• Cover in shockproof plastic.
Accessories
106/SLOPC - Rack (20 mm x 30 mm) in glass fibre with upper
106/SLOPC1 - Rack (20 mm x 30 mm) in glass fibre with lower
106/SLOAC - Rack in galvanised steel (22 mm x 22 mm)
106/SLOAC2 - Rack in galvanised steel (12 mm x 30 mm)
Q
950/xLbS
USER INSTRUCTIONS
During the opening/closing manoeuvre check for correct operation and
activate the emergency stop button in case of danger. During normal
operation wait for the gate to open completely before crossing it.
During blackouts with a flat battery the gate can be released and manu-
ally manoeuvred using the supplied release key (see manual release fig.
8). Periodically check the moving parts for wear and tear and grease if
required, using lubricants which maintain their friction levels unaltered
throughout time and are suitable for temperatures of -20 to +70°C.
In case of failure or operational anomalies switch off the power at the
mains, disconnect the batteries and do not attempt to repair the appli-
ance yourself. Eventual repair work must be carried out by specialised
personnel using original spare parts.
The appliance is not suitable for continuous operation and may only
be operated using a duty cycle of 90%.
PRELIMINARY CHECKS (fig. 1, page 2)
WARNING
AUTOMATIC OPENING
KEEP CLEAR
Before starting the installation make sure that the structure which is to
be automated is in good working order and respects the local standards
and regulations in force.
To this end ensure that:
CHILDREN OR PETS MUST NOT
bE ALLOWED TO PLAY ON OR
NEAR THE INSTALLATION
- The surface of the sliding gate "A" is smooth and has no protrusions
up to a distance of 2.5 m from ground level.
Protrusions on the gate surface which are not greater than 3 mm
and have rounded edges are acceptable.
If the surface of the gate is not smooth, the entire height up to
2.5 m from the ground must be protected by two of the following
devices:
a) photoelectric cells
b) contact safety buffer
- the distance "b" between the fixed parts and sliding parts of the
installation must not exceed 15 mm.
- the runner guide "C", preferably round, should be securely fixed to
the ground, completely exposed and free of any imperfections which
could inhibit the correct movement of the gate.
- when the gate is closed a space of 50 mm "D" must remain for the
entire height of the front part of the gate and a mechanical travel limit
"E" must be positioned on the upper part of the gate.
- The free space "D" can be covered with a rubber anti-crush buffer "F"
or better still a pneumatic or photoelectric contact safety buffer.
- if the gate slides past a fixed structure "G" which has railings or bars
leaving open spaces, it must be protected in one of the following
ways:
1. distance "H" greater than 500 mm: no protection required;
2. distance "H" between 500 and 300 mm: wire mesh fencing "I" or
punched metal plating "L" with an opening which does not allow the
passage of a 25 mm diameter sphere "M" must be fitted;
14
IMPORTANT REMARKS
. NOT READING THESE IMPORTANT
fastening slits (1 m).
fastening slits (1 m).
2 m to be welded.
1 m with fastening slits.
- Contact safety edge available in lengths of: