− [input number]  indicates which digital input (1 or 2)
− [function]  READ reads the count, RESET resets the count
Some examples:
PULSE 2 READ  reads the status of the pulse meter associated to input 2
PULSE 1 RESET  resets the pulse meter associated to input 1
• Pulse meter alarm setting
When a pulse meter threshold value is reached it is possible send a text message or a
ring to the contact numbers
PULSEALARM [input number][count][automatic reset]
− [input number] 
− [count] 
− [automatic reset]  AUTORESET to reset the time meter automatically upon
Some examples:
PULSEALARM 1 100  sends a text message of alarm when the count on input 1
PULSEALARM 2 300 AUTORESET  sends a text message of alarm when the count
• Setting the alarm text
To set the alarm text which will be sent to the contact numbers, use command:
DIGTXT [type][alarm text]
− [type] 
− [alarm text] 
NB: the alarm return text is saved by using the # separator between the 2
messages (the maximum length of each message remains 60 characters)
Example:
DIGTXT 1 motor alarm # end motor alarm
indicates which digital input (1 or 2)
indicates the count value that must trigger the alarm
(max 2
-1 counts) (0 disable alarm)
32
reaching the threshold (optional parameter)
reaches 100 pulses (it does not reset the meter)
on input 2 reaches 300 pulses, thus resetting the
meter
select input 1 or 2
any string of max 60 characters (including spaces)
- 46 -