Download Print this page

Orbis CODITEL 2 User Manual page 41

Gsm communication interface

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 31
The password field may be omitted if the command is given by qualified number.
Several commands may be included in one text message. In this case, the
commands executed will only be those whose reply is contained in a standard
text message (160 characters). To enter numbers with the decimal separator, you
need to use a full stop.
The structure of a reply to a command is similar to the command itself, with the addition of
the "=" symbol to indicate the current status. For example:
OUTKEY BLOCK  OUTKEY=BLOCK
• Set operation mode button (for admin only)
A quick press of the button allows it to act on the output.
To define the mode of behavior output using the command:
OUTKEY [functionality] with functionality that can assume the values:
− RING 
it reacts as it does to a call when the key is pressed
− TOGGLE  the key switches the output ON/OFF in bistable mode
− BLOCK 
disables the key functionality (it is not possible to access programming
mode when in this mode)
If the value is omitted, the current instrument status will be the response.
The default setting is RING.
• Caller control activation/deactivation (for admin only)
The caller number control can be disabled if you wish to temporarily allow anyone to
command the outputs via the command:
RINGCONTROL [status]
− ON  activates a control of the caller to check it is enabled
− OFF  disables the caller control function
If the value is omitted, the current instrument status will be the reply.
• Activation/deactivation of a text message of reply to a ring (for admin only)
A function can be activated to receive a text message following a ring, containing the
response of the instrument upon receiving the call with the command:
with status that can assume the values:
- 39 -
User Manual CODITEL 2

Advertisement

loading