Starting Rear Power Take-Off - Valtra Versu N Series Operator's Manual

Table of Contents

Advertisement

The light is lit when the PTO is on or the proportional ground speed power
take-off has been engaged.
The light blinks quickly if the PTO is rotating but no longer engaged.
The light blinks with normal speed when the PTO is not rotating and the gear
selected with the speed control knob is engaged.
The light blinks slowly if the PTO is not rotating and the gear selected with
the speed control knob is not engaged.
The light is not lit when the PTO is not on and the speed control knob is in
the N position.
3.19.2.3

Starting rear power take-off

You can start the power take-off (PTO) after you have activated the PTO by
selecting the PTO speed with the speed control knob.
You can start the rear PTO in two ways:
By using the switch for rear PTO. The switch for rear PTO has two positions,
on and off, and it returns to the centre position automatically.
By using the rear PTO on/off push button (optional) on the rear mudguard.
If the tractor is equipped with front PTO (optional), the front PTO switch on the
armrest is located in front of the rear PTO switch.
Start the rear PTO by pressing the switch down and pulling it backward.
The indicator light on the proline instrument panel is lit.
1
GUID-15597209-5561-4EBD-BA5E-A13223789DB0
1. Switch for rear PTO
- 269 -