Chapter 2
Planning Installation
This chapter contains installation requirements and system planning charts that
will help you prepare for installing the hub.

Installation Requirements

To help ensure a correct installation, read this section to determine the
environmental, electrical, spatial, and cable requirements.

Environmental Requirements

Be sure the operating environment for the hub is within the following ranges:
Temperature: 32 to 104 F (0 to 40 C)
Humidity: 5% to 95% (non-condensing)
Altitude: 0 to 10,000 feet (0 to 3 km)
Clearance: minimum of 2 inches (5.1 centimeters) on each side of the
hub (for proper ventilation)

Electrical Requirements

The electrical requirements for the hub are as follows:
Voltage: 100 to 240 VAC
Power: 2.0A (@ 100 VAC) to 1.0A (@ 240 VAC)
Frequency: 50 to 60 Hz
Compaq Netelligent 2724/2824 Dual-Speed Hub User Guide
2-1