15 –Cleaning, sanitising and maintenance of the incubator at the end of
cycle.
Cleaning, sanitising and maintenance operations must be performed with appliance off, unplugged and after a
sufficient time to allow hot parts to cool down.
Keep the appliance in a horizontal position and placed on a flat table.
The heating element (resistance) must be kept clean from dust and any dirt.
Cleaning incubator bottom: at the end of the cycle thoroughly wash the bottom of the incubator with a water
softener to remove any scaling left during water evaporation (do not use steel wool or scrapers to remove the
scale), rinse thoroughly with water to remove all water softener residues before moving to the sanitising stage in
order to avoid chemical reactions.
Sanitising incubator bottom: disinfect it with bleach or Amuchina (the one used for laundry is fine), then pour
about half a glass at the bottom of the incubator with a little water, shake the incubator so that the liquid covers
every part of the base including the walls, then rinse as well as possible.
MANDATORY: TO SANITISE THE INCUBATOR BASE ONLY USE BLEACH OR AMUCHINA! IT IS FORBIDDEN TO USE
ALCOHOL OR OTHER CHEMICALS.
If you disinfect the inside of the incubator with alcohol or other chemical detergents, when the incubator is used
again the residual chemical particles will affect the embryos leading to infections and resulting in death on
hatching.
Do not open the automatic egg turning unit of the incubator for any reason whatsoever.
Incubator cover plate cleaning: accurately clean the outside of the cover plate with a soft cloth moistened with
alcohol.
Blow the inside of the cover plate (along the perimeter of the protective grid) with compressed air to remove the
down lost by chicks during hatching. You can also use compressed air cylinders (those used to clean PC
keyboards).
NOTE: SANITISING MUST BE PERFORMED BEFORE INCUBATING
STORAGE: perfectly dry the inside of the incubator, operating it dry for 2/3 hours.
Store the incubator in a dry and clean place, away from shocks and changes in temperature.
Do not place any objects on top of the incubator.
No electrical maintenance is to be performed by the user.

15.1- Spare parts

Any product spare part can be found on the website www.borotto.com.

16 - Disposal

In implementation of Directives 2011/65/EU and 2012/19/EU, LEGISLATIVE DECREE 4 March 2014, n. 27 and
LEGISLATIVE DECREE 14 March 2014 , n. 49, relative to the use of hazardous substances in electrical and
electronic equipment and the disposal of waste, the symbol of the crossed wheelie bin, shown here, indicates
that at the end of its service life the product must be collected separately from other waste.
The user shall therefore deliver the appliance at the end of its service life to the suitable electric and electronic
separate waste collection facilities.
Appropriate separate collection for subsequent recycling of the decommissioned appliance, treatment and
environmentally compatible disposal contributes to avoiding possible negative effects on the environment and
health and promotes the recycling of the materials the appliance consists of
Unlawful disposal by the user involves the application of the administrative sanctions provided for by the laws in
force. The information related to the correct procedure of available collection systems must be obtained from the
Local Waste Disposal Service.