Troubleshooting; Wiring Diagram - Prince Castle Slim-Line 296 Series Operating Instructions Manual

Horizontal contact toaster
Table of Contents

Advertisement

TROUBLE SHOOTING
PROBLEM
Unit will not heat up.
Power rocker switch
light off.
Unit will not heat up.
Power rocker switch light on.
Unit heats up, but the
conveyor does not run.
Unit under and over
heats (does not respond to
thermostat adjustments).
Buns under or over done.

WIRING DIAGRAM

CAUSE
No power to unit.
Inoperable power cord.
Loose connection on power switch.
Inoperable power switch.
Inoperable thermostat.
Inoperable platen.
Loose motor switch connection.
Inoperable motor.
Stripped drive gear.
Loose chain sprockets
Gears not meshing.
Inoperable motor switch.
Inoperable thermostat.
Check platen adjustment.
(See Platen Adjustments on page 3).
Ensure power cord is connected to
proper Receptacle and the power inlet.
Replace power cord.
Tighten power switch connections.
Replace power switch.
Replace thermostat.
Replace platen.
Tighten motor switch connection.
Replace motor.
Replace drive gear.
Adjust and tighten sprockets.
Adjust conveyor set screws (See
Conveyor Adjustments on page 3).
Replace switch.
Replace thermostat.
Adjust platen for proper compression
7