SPECIFICATIONS Power Unit Order Code DYN/BAR/PMP Dimensions 305 x 145 x 100 Weight 1.8kg Rated Voltage 220/240V Cycle Time 15 minutes Electricity Safety Standard BS 5742, Part 1;IEC 601-1; EN 60601-1 Mattress Order Code DYN/BAR/MAT Dimensions Model A: 2040 x 1150 x 205mm Inflated Cell Height 130mm Weight...
Page x2 large cells INTRODUCTION x4 cable ties Call Sidhil Limited Service Dept for prices on 01422 233008 GENERAL SAFETY Mattress Covers can be supplied separately. INSTALLING YOUR SYSTEM Should you need more information than available in this manual, please do...
Page 4
COMPONENTS Power Unit - Made in Europe Pump Pump Filter Indicator 230Vac Input Linen Level 3.15 A T Main Switch FUSE TRIAC 230Vac 230Vac Filter Press. Low Pressure Closed Power ON Low Pressure Pressure GREEN LED RED LED Sensor Pressure sensor AS2P rev2 Circuit Diagram:...
8. Inspect state of power cable and check plug. proven long service life and has “ultra low vibration and sound” The Bariatric Dynamic can benefit Very High Risk patients with MATTRESS pressure ulcers grade 4. 9. Inspect all fastening straps.
GENERAL SAFETY DISINFECTION PROTOCOL The Bariatric Dynamic Alternating Air Mattress can be of effective service to you for many years if properly cared for. Before you use your Bariatric Dynamic alternating air mattress, please POWER UNIT familiarise yourself with the information in this user manual. Keep this manual in a handy place for future reference.
Page 7
AN AMBIENT TEMPERATURE RANGE OF – 40 C TO + 70 the Bariatric Dynamic air replacement mattress at the level of the hips. It should be possible to feel at least an inch of air filled clearance between the patient’s A RELITIVE HUMIDITY RANGE OF 10% TO 100% INCLUDING lowest point and the bed’s foam mattress underneath.
TROUBLESHOOTING SETTING UP 1) Should you be unsure as to whether the pump unit is switched on. Lay base directly on your bed frame with blue side with ‘Sidhil’ logo uppermost, Check List Solution noting labels showing foot end. Use central Green girth straps to fasten to bed Pump is plugged into mains? Plug fully into socket.
75-80 disease Discoloured 75-80 Broken/spot 81-+ anaemia Lay the base of your Bariatric Dynamic directly onto your bed frame. anaemia Broken/spot 81-+ Smoking Smoking The knee break will not affect efficiency due to hinging mechanism one third of the way up from the foot end.
RECOMMENDED WEIGHT/PRESSURE SETTING Reconnecting the connectors and switching the pump unit off, and then back on again, pump setting on 10, will re-inflate the Bariatric Dynamic . POWER FAILURE In the event of a power failure, disconnect the male and female connectors from the pump unit and then reconnect back together.