Programming On Main (Pom) - tams elektronik BiDiBooster Manual

Table of Contents

Advertisement

BiDiBooster

7.2. Programming on main (POM)

The configuration variables of the booster BiDiBooster can be set by
programming on main (POM). This is possible only with control units
supporting this programming mode.
In order to start programming the booster, input the value "62" for
CV#7 of any DCC locomotive address. Proceed as described in the
manual of your control unit. This input has no effect on a decoder with
the chosen address, as locomotive decoders do not allow setting a
value for CV#7 (= version).
After having started the programming mode (input the value "62" for
CV#7), the LED flashes quickly with a yellow light. You can now alter
the booster´s settings by choosing CV#7 again and inputting a value
from the following list.
If you do not input a value for CV#7 within 30 seconds, the
programming mode will be switched off. After setting the value the
programming mode is ended automatically. If you want to alter further
settings, you have to start the programming mode again by inputting
the value "62" for CV#7.
Function
Reset
Track voltage
(output value)
Default value: 18 V
Value for
Settings / Remarks
CV#7
8
Reset. Sets the values back to the
default values.
10
10 V
11
11 V
12
12 V
...
13 ... 23 V
24
24 V
English
Page 25