tams elektronik BiDiBooster Manual page 12

Table of Contents

Advertisement

English
Short-circuit protection
The BiDiBooster provides an intergrated short circuit breaking in shape
of an integrated current limitation. This causes the booster to switch off
automatically when a short circuit occurs at the track output and thus
prevents damages to the booster, the tracks and the vehicles. The time
elapsing till the short-circuit protection switches off the booster can be
set to a value between 1 and 250 milliseconds.
When the short circuit feedback line is connected to the booster port of
the control unit, the BiDiBooster sends a feedback to the DCC control
unit when a short circuit occurs and then the control unit switches off
the booster.
The short circuit sensitivity or the interrupting current, can be set to 2,
3, or 4 A. In order to prevent damage effectively when a short circuit
occurs, the short circuit sensitivity should not be set too high.
Rated size
Z and N
TT and H0
0, I and II
Please note:
!
The set short circuit sensitivity should not exceed the maximum
transformer´s current. In case the maximum interrupting current is
higher than the maximum transformer´s current, the booster cannot
detect an overcurrent and thus does not switch off the current to
protect electronic components, vehicles and the tracks from damage.
Risk of fire !
Page 12
Recommended short
circuit sensivity
(= interrupting current)
2 A
3 A
> 4 A
Value in state of delivery
3 A
BiDiBooster

Advertisement

Table of Contents
loading

This manual is also suitable for:

40-19507

Table of Contents