Power Supply - HP SignagePlayer mp8200 Quickspecs

Hp signageplayer mp8200: specifications
Hide thumbs Also See for SignagePlayer mp8200:
Table of Contents

Advertisement

QuickSpecs
Technical Specifications
Controller
Controller
Controller
Controller
Hard Drive Controller
Host SATA Controller
Unit Environment and Operating Conditions
Unit Environment and Operating Conditions
Unit Environment and Operating Conditions
Unit Environment and Operating Conditions
General Unit Operating Guidelines
Keep the computer away from excessive moisture, direct moisture and the extremes of heat and cold, to ensure that unit is
operated within the specified operating range.
Leave a 10.2 cm (4 in) clearance on all vented sides of the computer to permit the required airflow.
Never restrict airflow into the computer by blocking any vents or air intakes.
Do not stack computers on top of each other or place computers so near each other that they are subject to each other's re-
circulated or preheated air.
Occasionally clean the air vents on the front, back, and any other vented side of the computer. Lint, dust and other foreign
matter can block the vents and limit the airflow.
If the computer is to be operated within a separate enclosure, intake and exhaust ventilation must be provided on the
enclosure, and the same operating guidelines listed above will still apply.
Temperature Range
Relative Humidity
Maximum Altitude
(unpressurized)
* Operating temperature is de-rated 1.0 deg C per 300 m (1000 ft) to 3000 m (10,000 ft) above sea level, no direct sustained
sunlight. Maximum rate of change is 10 deg C/Hr. The upper limit may be limited by the type and number of options installed.

Power Supply

Power Supply
Power Supply
Power Supply
Standard Efficiency
High Efficiency
Operating Voltage
Range
Rated Voltage Range
Rated Line Frequency
Operating Line
Frequency Range
Rated Input Current
Rated Input Current
with
Energy
Efficient*
Power
Supply
Current Leakage
(NFPA 99)
Advanced Host Controller Interface (AHCI) Revision 1.2. The specification includes a description of the
hardware/software interface between system software and the host controller hardware.
1
The mp8200s model ships with the SATA controller in IDE mode
Operating: 50° to 95° F (10° to 35°
Non-operating: -22° to 140° F(-30° to 60° C)
Operating: 10% to 90% (non-condensing at ambient)
Non-operating: 5% to 95% (non-condensing at ambient)
Operating: 10,000 ft (3048 m)
Non-operating: 30,000 ft (9144 m)
Integrated graphics:
Discrete graphics:
DA - 14115
North America — Version 2 — October 28, 2011
mp8200 and mp8200s
mp8200 and mp8200s
mp8200 and mp8200s
mp8200 and mp8200s
1 each
C)*
mp8200 and mp8200s
mp8200 and mp8200s
mp8200 and mp8200s
mp8200 and mp8200s
N/A
135W active PFC 87% efficient
180W active PFC 87% efficient
90 - 264 VAC
100 - 240 VAC
50/60 Hz
47 - 63 Hz
N/A
135W: 2.4A
180W: 2.9A
< 250 µA
HP SignagePlayer mp8200 Series
HP SignagePlayer mp8200 Series
HP SignagePlayer mp8200 Series
HP SignagePlayer mp8200 Series
1
Page 10

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SignagePlayer mp8200 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

This manual is also suitable for:

Signageplayer mp8200s

Table of Contents