For the Installer

General
NIBE VPB is a series water heater, which is suitable for
connection to heat pumps, gas or oil-fired boilers.
The water tank consists of a steel jacket, with a copper
lining to protect against corrosion. The water heater is
equipped with a copper finned tube (two finned tubes
in VPB 1000).
The water heater is designed and manufactured for a
maximum cut-off pressure of 10 bar. Maximum permit-
ted temperature is 95 °C.
The insulation is polyurethane, which provides excellent
heat insulation. The insulation and grey plastic outer
cladding can be removed to make it easier to move the
water heater through doorways, for example.
NIBE VPB is equipped with submerged tube for control
of hot water heating.
VPB 500 can be equipped with an immersion heater and
VPB 750 and VPB 1000 can be equipped with up to two
immersion heaters.
Transport
NIBE VPB should be transported and stored vertically in
a dry place. The NIBE VPB may, however, be carefully laid
on its back when being moved into a building.
Assembly
The water heater is only designed for upright installation.
The water heater is unscrewed from the pallet and lifted
into position, using the lifting eye at the top.
The top insulation must be removed to access the lifting
eyes on the VPB 750 and VPB 1000.
Position NIBE VPB on a firm base that can take the
weight, preferably on a concrete floor or foundation.
Use the product's adjustable feet to obtain a horizontal
and stable set-up.
20-55 mm
30 - 50 mm
NIBE VPB | GB
0
R
0
R
Supplied components
VPB 500
Drain valve with plug
Insulation plug
VPB 750
Drain valve with plug
VPB 1000
Drain valve with plug
4 x. Copper pipe Ø 28 mm
3 x T-pipe connectors
Insulation
Cover discs
Cover discs
H o t w a te r 5 1 °C
H M flo w 4 9 (5 0 )
°C
-2
0
+ 2
0
1
R
Cover discs
3 x Angle connectors
Venting nipple
H M flo w 4 9 (5 0 )
°C
H o t w a te r 5 1 °C
-2
0
+ 2
1
0
R
19