Com Config Window; Tuning - Leadshine Technology DM432 User Manual

Fully digital stepping driver
Table of Contents

Advertisement

l
Exit: Exit the ProTuner.

Com Config Window

Figure 21: RS232 communication configuration window
Serial Port: Select the serial communication port to which the driver is connected. The factory default
setting is COM1.
Baud Rate: Select the communication baud rate. The factory default setting is 38400.
Click Open button to establish a connection with the specified settings. When connecting, you can
choose SaveToDrive to download the current parameter settings to the driver, or to upload the stored
driver settings into the ProTuner by clicking Tuning > Position Loop on the menu bar.

Tuning

The user can choose one or two drop-down menu(s) by clicking Tuning, including CurrentLoop and
SystemConfig.
l
CurrentLoop: In Current Tuning window, the user can tune the Kp (Proportional Gain) and
Ki (Integral Gain) of driver's current loop to optimize responses with different motors.
Start/Restart a Step Response test to get an optimum response.
Kp: Proportional Gain. Proportional Gain determines the response of the driver to current setting
command. Low Proportional Gain provides a stable system (doesn't oscillate), has low stiffness, and
large current error, causing poor performances in tracking current setting command in each step like
Figure 23. Too large Proportional Gain values will cause oscillations and unstable systems.
Tel: +086 0755-26434369
DM432 Digital Stepping Driver Manual V1.0
21
Web Site: www.leadshine.com
Figure 22: Current Tuning window
Ki: Integral Gain. Integral Gain helps the driver to overcome static current errors. A low or zero
value for the Integral Gain may have current errors at rest. Increasing the Integral Gain can reduce the
error. If the Integral Gain is too large, the systems may "hunt" (oscillate) about the desired position.
Start button: The user can start a Step Response test by clicking this button. Start/Restart a Step
Response test to get an optimum response like Figure 22, and remember to save the settings to the
driver when finish tuning. See Figure 24.
Figure 23: Kp=2604, Ki=0 (poor performances)
Tel: +086 0755-26434369
DM432 Digital Stepping Driver Manual V1.0
22
Web Site: www.leadshine.com