Run-Time Errors - HP Kayak XU04 Features Manual

Maxilife hardware monitoring
Hide thumbs Also See for Kayak XU04:
Table of Contents

Advertisement

Table 3
Test
During normal usage of the PC, HP MaxiLife
continually checks vital system parameters. If an
error should occur, a message would be
automatically displayed on the LCD panel.
1.
Special cases: Board PLL = System board needs replacing. CPU error = Reset or power off the system to recover.
HP MaxiLife® Hardware Monitoring
HP MaxiLife Test Sequence and Error Messages

Run-Time Errors

During the normal usage of the PC, HP MaxiLife continualy checks some of
the vital system parameters. These include: temperature errors, fan
malfunctions, power voltage drops, board PLL problems and CPU problems.
If several alarms or errors are active at the same time, they will be displayed
by cycling every second through four "alarm sources", with one error cause
for each source:
• Pre-boot diagnostics.
• Run-Time error 1.
• Run-Time error 2.
• POST error.
The run-time errors are organized into two different sources.
Run-Time error 1: "Temperature I/O slot", "Power errors", "Fan CPU",
"Board PLL".
Run-Time error 2: "Temperature disk", "Temperature CPU", "Fan disk",
"Fan I/O slot", "CPU error".
If both fan for disks and I/O slot are not connected (both are run-time
error 1), only the "Fan disk" (run-time error 2) will be displayed.
Run-Time Errors
Error Code
FAN CPU
Main Menu
The main menu is displayed when any of the LCD buttons from are presed
(HP MaxiLife LCD status panel can be accessed even though the PC is
turned off). The Main Menu comprises of three sub-menus: System Info,
Boot Steps and Diagnostics.
10
Action to Take
• Check the connection of the corresponding component, which
could be: "Temp IO slot", "Power errors, "Fan CPU", "Board
PLL", "Temp disk", "Temp CPU", "Fan disk", "Fan IO slot", "CPU
1
error".