Advertisement

Typical Diag Error
Messages
When the Processor and VRM are
correctly installed, the "smiling
icon" is shown on the LCD status
panel.
If the Processor has only been
partly inserted in the processor slot
(opposite side to the VRM), then the
displayed message will indicate a
CPU socket error.
If the Processor has only been
partly inserted in the processor slot
(closest side to the VRM), then the
displayed message will indicate a
Power CPU 1 error.
The Processor has not been inserted
correctly in the processor slot. The
displayed message will indicate a
CPU socket error.
The Processor has been correctly
installed in the processor slot. How-
ever, the VRM is not installed. The
displayed message will indicate a
Power CPU 1 error.
There is no installed Processor.
However, the VRM is correctly
installed. The displayed message
will indicate a Power error.
If one of the following fatal malfunctions occur, the displayed message will
indicate a BIOS error:
The BIOS no longer works.
There is no Flash.
HP MaxiLife® Hardware Monitoring
HP MaxiLife Test Sequence and Error Messages
14
Processor
Processor
Processor
HP KAYAK XU
VRM
Error!
VRM
CPU Socket
Error!
VRM
Power CPU 1
Error!
VRM
CPU Socket
Power CPU 1
Error!
VRM
Power supply
Error!
BIOS
Error!