Hilti HDE 500-A12 Manual page 27

Hide thumbs Also See for HDE 500-A12:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 21
Status
1 LED flashes.
4
Technical data
Weight in accordance with EPTA Procedure 01, without battery
Rated voltage
Storage temperature
Ambient temperature for operation
4.1
Battery
Battery operating voltage
Weight, battery
Ambient temperature for operation
Storage temperature
Battery charging starting temperature
4.2
Noise information and vibration values in accordance with EN 62841
The sound pressure and vibration values given in these instructions were measured in accordance with a
standardized test and can be used to compare one power tool with another. They can also be used for a
preliminary assessment of exposure.
The data given represent the main applications of the power tool. However, if the power tool is used for
different applications, with different accessory tools, or is poorly maintained, the data can vary. This can
significantly increase exposure over the total working period.
An accurate estimation of exposure should also take into account the times when the tool is switched off, or
when it is running but not actually being used for a job. This can significantly reduce exposure over the total
working period.
Identify additional safety measures to protect the operator from the effects of noise and/or vibration, for
example: maintaining the power tool and accessory tools, keeping the hands warm, organization of work
patterns.
Noise information
Typical A-weighted sound power level (L
Uncertainty for measured sound power level (K
Typical A-weighted emission sound pressure level (L
Uncertainty for the sound pressure level (K
Vibration information
Total vibration (a
)
h
Uncertainty (K
)
ah
*2330324*
Meaning
Battery charge state cannot be displayed while the
control switch is pressed and for up to 5 seconds
after releasing the control switch.
)
WA
)
WA
pA
)
pA
2330324
Charge state: < 10 %
HDE 500-A12
1.8 kg
10.8 V
−40 ℃ ... 85 ℃
−17 ℃ ... 60 ℃
10.8 V
See the end of these
operating instructions
−17 ℃ ... 60 ℃
−40 ℃ ... 85 ℃
−10 ℃ ... 45 ℃
HDE 500-A12
75.5 dB
3 dB
)
64.5 dB
3 dB
B 12/2.6 Li-Ion
0.2 m/s²
B 12/4.0 Li-Ion
0.2 m/s²
1.5 m/s²
English
19