[ENG] NetPing 2/PWR-220 v3/ETH & NetPing 2/PWR-220 v4/SMS, User guide - Содержание [ENG] [2PWR,v2SMS] About What and for Whom Is This Document?....... 5 [ENG] [2PWR,v2SMS] Liability Limitation and Copyright.......... 6 [ENG] [2PWR,v2SMS] Shipping Kit of a Device............7 [ENG] [2PWR,v2SMS] Device Overview: Appearance and Basic Specifications of a Device ..........................
Page 3
[ENG] NetPing 2/PWR-220 v3/ETH & NetPing 2/PWR-220 v4/SMS, User guide - [ENG] [2PWR,v2SMS] Firmware Update..............30 [ENG] [2PWR,v2SMS] Warranty................. 31 [ENG] [2PWR,v2SMS] Where to Get a Document with a Firmware Description?..32 [ENG] [2PWR,v2SMS] What Should I Do if I Have More Questions? ......33...
[ENG] NetPing 2/PWR-220 v3/ETH & NetPing 2/PWR-220 v4/SMS, User guide -[ENG] [2PWR,v2SMS] About What and for Whom Is This Document? [ENG] [2PWR,v2SMS] About What and for Whom Is This Document? The document contains preparation of devices NetPing 2/PWR-220 v3/ETH and NetPing 2/PWR-220 v2/SMS for the operation, external electric interfaces and specifics of the operation.
User Guide, as well as firmware and software of devices and this User Guide belong to NetPing global Ltd. Сopying, replication and translation of this user guide to other languages are not allowed without a prior written permission are not allowed without a of a rightholder.
[ENG] NetPing 2/PWR-220 v3/ETH & NetPing 2/PWR-220 v4/SMS, User guide -[ENG] [2PWR,v2SMS] Device Overview: Appearance and Basic Specifications of a Device [ENG] [2PWR,v2SMS] Device Overview: Appearance and Basic Specifications of a Device It is possible to plug up to two electricity consumers with a total capacity of 1000 Watts to a device through controlled electric 220V sockets.
Page 10
[ENG] NetPing 2/PWR-220 v3/ETH & NetPing 2/PWR-220 v4/SMS, User guide -[ENG] [2PWR,v2SMS] Device Overview: Appearance and Basic Specifications of a Device Picture 2 – Front view (NetPing 2/PWR-220 v2/SMS device) Picture 3 – Front panel (NetPing 2/PWR-220 v3/ETH device) [ENG] [2PWR,v2SMS] Device Overview: Appearance and Basic Specifications of a Device...
[ENG] NetPing 2/PWR-220 v3/ETH & NetPing 2/PWR-220 v4/SMS, User guide -[ENG] [2PWR,v2SMS] Device Overview: Appearance and Basic Specifications of a Device Picture 4 – Front panel (NetPing 2/PWR-220 v2/SMS device) Picture 5 – Back panel (NetPing 2/PWR-220 v3/ETH, NetPing 2/PWR-220 v2/SMS devices) Elements of a Front Panel •...
[ENG] NetPing 2/PWR-220 v3/ETH & NetPing 2/PWR-220 v4/SMS, User guide -[ENG] [2PWR,v2SMS] Device Overview: Appearance and Basic Specifications of a Device Elements of a Back Panel • Sockets for connecting a load that are «computer sockets». A load is connected using a specific cable «monitor –...
[ENG] NetPing 2/PWR-220 v3/ETH & NetPing 2/PWR-220 v4/SMS, User guide -[ENG] [2PWR,v2SMS] Connecting, Installing, and Initial Configuration of a Device [ENG] [2PWR,v2SMS] Connecting, Installing, and Initial Configuration of a Device The page has photos of a NetPing 2/PWR-220 v2/SMS device in the text.
Page 14
[ENG] NetPing 2/PWR-220 v3/ETH & NetPing 2/PWR-220 v4/SMS, User guide -[ENG] [2PWR,v2SMS] Connecting, Installing, and Initial Configuration of a Device 4. Plug the equipment, power of which must be controlled, to «PWR» sockets on a back panel of a device. To make a connection convenient, use the «monitor – system unit»...
Page 15
Glowing of a link LED near a corresponding Ethernet port on a front panel of a device will mean that a connection is successfully established. The second Ethernet port may be used to plug any Ethernet devices including other NetPing devices, in a «chain».
Page 16
[ENG] NetPing 2/PWR-220 v3/ETH & NetPing 2/PWR-220 v4/SMS, User guide -[ENG] [2PWR,v2SMS] Connecting, Installing, and Initial Configuration of a Device A device is connected and ready to work. A device that has been purchased right now or a device for which a procedure of resetting parameters to default values has been performed (see...
[ENG] NetPing 2/PWR-220 v3/ETH & NetPing 2/PWR-220 v4/SMS, User guide -[ENG] [2PWR,v2SMS] Using IO Lines in the «Output» Mode to Control External Devices [ENG] [2PWR,v2SMS] Using IO Lines in the «Output» Mode to Control External Devices Input-Output (IO) lines of a device can be used for an input work as well as in an output mode for managing external devices.
[ENG] NetPing 2/PWR-220 v3/ETH & NetPing 2/PWR-220 v4/SMS, User guide -[ENG] [2PWR,v2SMS] Using IO Lines in the «Output» Mode to Control External Devices Equivalent Сircuit [ENG] [2PWR,v2SMS] Using IO Lines in the «Output» Mode to Control External Devices – ...
[ENG] NetPing 2/PWR-220 v3/ETH & NetPing 2/PWR-220 v4/SMS, User guide -[ENG] [2PWR,v2SMS] Plugging External Sensors [ENG] [2PWR,v2SMS] Plugging External Sensors It is prohibited to plug sensors and external modules into NetPing devices when a power supply is on! Configuring a device and receiving notifications from sensors can be seen in the document «Firmware...
[ENG] NetPing 2/PWR-220 v3/ETH & NetPing 2/PWR-220 v4/SMS, User guide -[ENG] [2PWR,v2SMS] Plugging External Sensors Contact Description Contacts of a digital bus i2C, data line Power voltage +5V Ground (common) Plugging temperature sensors T811 Eight temperature sensors are plugged in parallel one to another in the same terminals. ...
[ENG] NetPing 2/PWR-220 v3/ETH & NetPing 2/PWR-220 v4/SMS, User guide -[ENG] [2PWR,v2SMS] Plugging External Sensors Depending on ID, a temperature sensor will be displayed on a corresponding channel in a web interface of a device. A sensor is packaged with an inseparable cable, with connectors on the ends. A cable length can be increased with the help of flat cable extenders of...
[ENG] NetPing 2/PWR-220 v3/ETH & NetPing 2/PWR-220 v4/SMS, User guide -[ENG] [2PWR,v2SMS] Plugging External Sensors A sensor is packaged with an inseparable cable, with connectors on the ends. A cable length can be increased with the help of flat cable extenders of RC-4 sensor, which are sequentially plugged one into another.
[ENG] NetPing 2/PWR-220 v3/ETH & NetPing 2/PWR-220 v4/SMS, User guide -[ENG] [2PWR,v2SMS] Plugging External Sensors Plugging a door sensor A sensor is a «dry contact», therefore the order of connecting wires is irrelevant. The number of plugged sensors is limited only by a number of free IO lines.
[ENG] NetPing 2/PWR-220 v3/ETH & NetPing 2/PWR-220 v4/SMS, User guide -[ENG] [2PWR,v2SMS] Plugging External Sensors Plugging NetPing AC/DIN sockets The number of plugged NetPing AC/DIN sockets is limited only by a number of free IO lines. When connecting a socket to a device, all wires are used, except a brown (white) one. An IO line, to which a NetPing AC/DIN socket is connected, needs to be switched into the «output»...
[ENG] NetPing 2/PWR-220 v3/ETH & NetPing 2/PWR-220 v4/SMS, User guide -[ENG] [2PWR,v2SMS] Resetting Parameters to Default Values [ENG] [2PWR,v2SMS] Resetting Parameters to Default Values Resetting parameters of a device to default values is necessary in the next cases: • login and/or password for accessing a web interface of a device is lost;...
Page 27
[ENG] NetPing 2/PWR-220 v3/ETH & NetPing 2/PWR-220 v4/SMS, User guide -[ENG] [2PWR,v2SMS] Resetting Parameters to Default Values User name: visor Password: ping IP address: 192.168.0.100 Subnet mask: 255.255.255.0 Gate (gateway): is not set SNMPcommunity: SWITCH MAC address: 00 a2 xx xx xx xx Here, xx xx xx xx corresponds to a serial number of a device. Therefore, all devices have unique MAC addresses after being manufactured.
[ENG] NetPing 2/PWR-220 v3/ETH & NetPing 2/PWR-220 v4/SMS, User guide -[ENG] [2PWR,v2SMS] Operating, Storage, Transportation and Disposal Conditions [ENG] [2PWR,v2SMS] Operating, Storage, Transportation and Disposal Conditions It is allowed to use a device only in excellent technical condition and only for intended purpose according to a user guide.
[ENG] NetPing 2/PWR-220 v3/ETH & NetPing 2/PWR-220 v4/SMS, User guide -[ENG] [2PWR,v2SMS] Safety Precautions [ENG] [2PWR,v2SMS] Safety Precautions The next information will allow users to avoid both injuries and damaging a device as well as connected equipment. • A device must be plugged to a power supply socket with a ground or a hole, where a contact is inserted. A contact must be located at a plug and be connected to a ground wire.
[ENG] NetPing 2/PWR-220 v3/ETH & NetPing 2/PWR-220 v4/SMS, User guide -[ENG] [2PWR,v2SMS] Firmware Update [ENG] [2PWR,v2SMS] Firmware Update A device supports firmware update through a web interface of a device. More details are provided in the document «Software Description». Where to get a document with a firmware description? [ENG] [2PWR,v2SMS] Firmware Update ...
[ENG] NetPing 2/PWR-220 v3/ETH & NetPing 2/PWR-220 v4/SMS, User guide -[ENG] [2PWR,v2SMS] Warranty [ENG] [2PWR,v2SMS] Warranty The manufacturer guarantees normal operation of the product within 24 months from the date specified on the warranty sticker if a buyer follows operating and storage conditions. Manufacturer warranty applies only to failure of a device which occurred because of defects in manufacturing process of products and components used.
[ENG] NetPing 2/PWR-220 v3/ETH & NetPing 2/PWR-220 v4/SMS, User guide -[ENG] [2PWR,v2SMS] Where to Get a Document with a Firmware Description? [ENG] [2PWR,v2SMS] Where to Get a Document with a Firmware Description? Configuration and operation order with control interfaces of a device are provided in the document «Firmware...
[ENG] NetPing 2/PWR-220 v3/ETH & NetPing 2/PWR-220 v4/SMS, User guide -[ENG] [2PWR,v2SMS] What Should I Do if I Have More Questions? [ENG] [2PWR,v2SMS] What Should I Do if I Have More Questions? Technical support for Netping devices Manufacturer's website: http://www.netpingdevice.com/ Kindly see our blog for articles with examples of using the devices and news on issuing new firmware versions.