Kenwood CS-5140 Instruction Manual page 11

40mhz dual trace oscilloscope
Table of Contents

Advertisement

AV2:
T w o horizontal cursor lines are displayed on the
C R T , and voltage difference and voltage ratio
between them are displayed in the upper right
on the C R T posterior to the cursor measure-
ment mode display.
Setting the C H 2 V A R I A B L E controller (7)
the C A L position causes voltage
measurement, and a value calculated in accor-
dance with setting of the C H 1 V O L T S / D I V dial
(D
is displayed posterior to ^1V2.
Setting the C H 2 V A R I A B L E controller (f)
the
U N C A L position
measurement, and a value calculated on the
basis of 5 div. as 1 0 0 % is displayed posterior
to the R A T I O .
A
When
the
cursor
cursor, a minus value is displayed.
NOTE: Setting of the MODE select switch (Tj)
to
the
CH1
mode cursor measurement.
Setting of the MODE select switch %
to
the
X - Y position
mode measurement.
AT:
T w o vertical cursor lines are displayed on the
C R T , and time difference and time ratio bet-
ween them are displayed in the upper right on
the C R T posterior to the cursor measurement
mode display.
Setting the S W E E P V A R I A B L E controller (§) to
the
C A L
position
measurement, and a value calculated in accor-
dance with setting of the S W E E P TIME/DIV dial
@) is displayed posterior to AT.
Setting the S W E E P V A R I A B L E controller @
the U N C A L position causes time ratio measure-
ment, and a value calculated assuming that
5 div. is 1 0 0 % is displayed posterior to the
R A T I O .
When the A cursor is on the left of the A
REF cursor, a minus value is displayed.
NOTE: Setting of the MODE select switch @)
to
the
X - Y
mode measurement.
to
difference
to
causes
voltage
ratio
is
below
the
^IREF
AVI
position
causes
AV2
disables
causes
time
difference
to
AT
position
disables
1/AT:
T w o vertical cursor lines are displayed on the
C R T , and frequency and phase difference bet-
ween them are displayed in the upper right on
the C R T posterior to the cursor measurement
mode display.
Setting the S W E E P V A R I A B L E controller (§) to
the C A L position causes frequency measure-
ment, and a value calculated in accordance
with setting of the S W E E P TIME/DIV dial @ is
displayed posterior to MAT.
Setting the S W E E P V A R I A B L E controller (§) to
the U N C A L position causes phase difference
measurement, and a value calculated assuming
that 5 div. is 3 6 0 ° is displayed posterior to the
P H A S E .
When the A cursor is on the left of the A
REF cursor, a minus value is displayed. However,
frequency is displayed in an absolute value.
NOTE: Setting of the MODE select switch
the X - Y position disables MAT mode
measurement.
to
11