Keep all flammable objects away from the appliance (paper, rags, plastic, polystyrene, etc.).
The minimum distance for exhaust pipes from flammable materials must be at least 25 cm.
Do not place household appliances underneath the appliance as they could be damaged if the safety valve intervenes, if the
drain trap is blocked, or if there are leaks from the hydraulic connections; otherwise, the manufacturer cannot be held respon-
sible for any damage caused to the household appliances.
For the aforementioned reasons, we recommend not placing furnishings, furniture, etc. under the appliance.
Any modification to the appliance that is not explicitly indicated in this section of the booklet is forbidden.
Installation standards
This appliance can be installed outdoors in a partially protected area.
By partially protected area, we mean one in which the unit is not directly exposed to the elements (rain, snow, hail, etc.).
This type of installation is possible when permitted by the laws in force in the appliance's country of destination.
Installation of gas appliances, flue exhaust pipes and combustion air intake pipes is forbidden
in places with a fire risk (for example: garages, closed parking stalls), and in potentially dan-
gerous places.
Do not install on the vertical projection of hobs.
Do not install in places/rooms that constitute public areas of apartment buildings, internal
stairways or other escape routes (e.g. floor landings, entrance halls, etc.).
Installation is also forbidden in places/rooms that constitute public areas of apartment build-
ings such as cellars, entrance halls, attics, lofts, etc., unless otherwise provided for by local
regulations in force.
These appliances, if not adequately isolated, are not suitable for installation on walls of com-
bustible material.
Installing the wall recessed frame kit must guarantee the boiler stable, efficient support.
The recessed frame kit ensures appropriate support only if installed correctly (according to the rules of good practice), following the in-
structions on its instructions leaflet.
The recessed frame for the boiler is not a supporting structure and must not replace the wall removed. It is necessary to position the boiler
inside the wall.
For safety reasons against any leaks it is necessary to plaster the boiler housing in the brick wall.