Immergas VICTRIX OMNIA Manual page 79

Hide thumbs Also See for VICTRIX OMNIA:
Table of Contents

Advertisement

Id
Parameter
Parameter
t9
Display
Flow off
t10
temperature
increase
t11
Id
Parameter
Parameter
Hydraulic
A0
model
A1
-
Circulating
A2
pump model
Maximum
A3
pump speed
Minimum
A4
pump speed
Circulating
A5
pump mode
Id
Parameter
Parameter
F0
Flue length
F1
-
In the event of an alteration, anomaly "E72" appears and fast calibration is required.
Description
Establishes what the indicator 11 displays (Fig. 38).
"Summer" mode:
0: the indicator is always off
1: active pump displays the flow temperature, pump off the
indicator is off
"Winter" mode:
0: always displays the value set on the C.H. selector
1: active pump displays the flow temperature, pump off
always displays the value set on the C.H. selector
Increases the flow off temperature at ignition only in the first
60 seconds. After the flame is detected, the temperature is
increased by t10
Not used on this boiler model
Description
Defines the type of hydraulics in the boiler
Not used on this boiler model
Defines the type of circulator in the boiler
Sets the maximum pump operating speed
Sets the minimum pump operating speed
Sets the pump operating mode
- DELTA T = 0: proportional head (Parag. 1.29 - 1.30)
- DELTA T = 5 - 25 K: ∆T constant (Parag. 1.29 - 1.30)
Description
Defines the length of the flue (Par. 3.12)
Not used on this boiler model
Range
Default
0 - 1
1
0 - 15
0
0 - 1
0
Range
Default
0
0
-
-
0 ÷ 1
0
1 ÷ 9
9
1 ÷ A3
7
0 ÷ 25
15
Range
Default
0 - 2
0
-
-
Value
value
Value
value
Value
value
79

Hide quick links:

Advertisement

Table of Contents
loading