Error
Anomaly signalled
Code
Combustion control
77
fault
Combustion control
78
fault
Combustion control
79
fault
Block - gas valve
80
driver issue
Combustion anomaly
- power reduction in
84
progress
Block - gas valve
87
control
Block - gas valve
88
control
Combustion signal
89
unstable
Combustion signal
90
beyond limit
Incorrect ignition
91
block
Fan revs correction
92
limit
Combustion signal
93
beyond limit
Combustion anomaly
94
Combustion signal
95
discontinuous
Clogged flue
96
Block - maximum no.
98
of software errors
General block
99
(1) If the shutdown or fault persists, contact an authorised company (e.g. Authorised Service Centre)
(2) The anomaly can only be verified in the list of errors in the "Information" menu
Cause
Out of range current is detected on the gas valve.
High current on the gas valve is detected.
Reduced current on the gas valve is detected.
This occurs in the event of malfunctions of the P.C.B. that
controls the valve.
Faulty valve
A low supply pressure is detected on the gas line. As a result
the appliance power is limited and the anomaly is reported.
A malfunction of one of the components that controls the
gas valve has been detected.
A malfunction of one of the components that controls the
gas valve has been detected.
The flame is unstable due to: presence of flue gas recircula-
tion, wind, unstable gas pressure, unstable fan speed, or
due to system malfunction.
The combustion signal is beyond the adjustment range re-
quired for an extended period of time.
The board has exhausted all possible actions in order to ob-
tain optimal ignition of the burner.
The system has exhausted all possible corrections of the
number of fan revs.
The combustion signal is beyond the adjustment range re-
quired for a limited period of time.
A problem is detected on the combustion control, which
may be due to: gas low pressure, flue recirculation, defective
gas valve or P.C.B.
The system detects a discontinuous combustion signal.
This occurs in the event an obstruction is detected in the
flue system.
The maximum number of software errors possible has been
reached.
A boiler anomaly has been detected.
Boiler status / Solution
The boiler does not start (1)
The boiler does not start (1)
The boiler does not start (1)
Press the Reset button (1)
If normal conditions are restored the
boiler restarts without having to be
reset (1) (2)
The boiler does not start (1)
The boiler does not start (1)
The boiler keeps working (1) (2)
The boiler keeps working (1) (2)
Press the Reset button (1)
The boiler keeps working (1) (2)
The boiler keeps working (1) (2)
If normal conditions are restored the
boiler restarts without having to be
reset (1) (2)
The boiler keeps working (1) (2)
The boiler does not start (1)
If normal conditions are restored the
boiler restarts without having to be
reset
Press the Reset button (1)
Press the Reset button (1)
57