Winter
+
In this mode the boiler works both for producing domestic hot water and for central heating. The temperature of the DHW is always reg-
ulated via buttons
, the central heating temperature is regulated via buttons
play by the indicator
. In the central heating mode, if the temperature of the water contained in the system is sufficient to heat the radi-
ators, the boiler can only function with the activation of the pump.
From this moment the appliance functions automatically. With no demand for heat (central heating or domestic hot water production)
the boiler goes to "standby" function, equivalent to the appliance being powered without presence of flame.
Each time the burner ignites, the relative flame symbol
Operation with Comando Amico Remoto (Remote control)
If the CAR
is connected, the
V2
panel and the
button remains active on the boiler control panel, along with
where the functioning state is shown.
If the appliance is put into "off" mode, the "ERR>CM" connection error symbol will appear on the CAR
er powered constantly so as not to lose memorised programs.
Solar function
This function is automatically activated if the "t3" is more than 0 seconds.
During a withdrawal, as long as the "Solar ignition delay" function is active, the boiler does not switch on; the D.H.W. withdrawal symbol
flashes on the display along with the flashing solar function symbol
When the "Solar ignition delay" time has elapsed, the boiler switches on.
Operation with optional external probe
In the case of a system with external probe, the boiler flow temperature for room central heating is managed by the external probe de-
pending on the external temperature measured (Par. 1.11). The flow temperature can be modified by selecting the functioning curve via
buttons
(or from the control panel of CAR
With external probe present, the relative symbol
"Stand-by" Mode
Press the "Stand-by" button until the
ti-block function and three-way and signalling of any anomalies is guaranteed.
OFF mode
By holding the
button down for 8 seconds, only the frame of the symbol
The safety functions are not guaranteed in this mode.
In "Stand-by" and "Off" mode, the appliance is to be considered still live.
is displayed.
symbol will appear on the display. The boiler regulation parameters can be set via the CAR
(optional).
, if it is connected to the boiler), selecting a value from "0 to 9".
V2
will appear on the display.
symbol appears; from this moment the boiler remains off. The antifreeze function, pump an-
and the relative temperature is shown on the dis-
(CAR
)
(optional)
V2
V2
for switch-off ("off" mode only) and the display
.
remains lit on the display and the boiler is off completely.
control
V2
. The CAR
is howev-
V2
V2