RX1250 Real-Time SmartNet Corrections Via a Siemens MC75
System 1200 Guide - RX1250 Real-Time SmartNet
This guide describes how to configure your RX1250 SmartRover.
With a Siemens MC75 on the clip using a GPRS Data plan for
connecting to SmartNet
Topics

Introduction

Leica UK Technical Support Group
Corrections Via a Siemens MC75

• Establish a Connection between the RX1250 and the Siemens Module

• Establish a Connection between the RX1250 and SmartNet via Mobile
Phone Internet Connection
Many of the mobile phone providers today offer GPRS enabled phones
with Bluetooth capability. As a result, these mobile phones may be utilised
to log onto the Internet and receive correction data from the SmartNet
reference network.
Notice: You will need to have a GSM mobile phone with a GPRS Data
Plan from a UK provider, such as Vodafone, Orange, T-Mobile etc...

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RX1250 SmartRover and is the answer not in the manual?

Questions and answers

Summary of Contents for Leica RX1250 SmartRover

  • Page 1 RX1250 Real-Time SmartNet Corrections Via a Siemens MC75 System 1200 Guide - RX1250 Real-Time SmartNet Corrections Via a Siemens MC75 This guide describes how to configure your RX1250 SmartRover. With a Siemens MC75 on the clip using a GPRS Data plan for connecting to SmartNet Topics •...
  • Page 2 CONFIGURE Internet Interface screen. From the CONFIGURE Internet Interface screen: • Set the Internet to Yes • Set the Port to Clip-On Select Device – by pressing F5 and select Siemens MC75 and F1 Continue Leica UK Technical Support Group...
  • Page 3 Vodafone internet mobile.o2.co.uk Orange orangeinternet T-Mobile general.t-mobile.uk If you are using another mobile provider please contact them directly for your GPRS APN. Press F1 (CONT). This will take you back to the CONFIGURE Interfaces screen. Leica UK Technical Support Group...
  • Page 4 Configure the settings as shown: • Enter YOUR appropriate SmartNet username and SmartNet password in the required fields. • Enter MAX-RTCMv3 into the Mountpoint field. Press F1 twice to return to the Configure Interfaces screen. Leica UK Technical Support Group...
  • Page 5 Enter the IP Address as 217.146.121.30 Enter the IP Port as 7830 Press F1 Store. Highlight the Server that you wish to connect to and press F1 Cont. Make sure Auto Connect is set to NO and press F1 Cont Leica UK Technical Support Group...
  • Page 6 • Press the F1 (CONT) button to return to the Main Menu. You may now create a new job file to begin your survey project. Then within your survey it is possible to connect and disconnect as required with Shift F3. Leica UK Technical Support Group...