PROGRAMMING
TABLE 9 (CONTINUED)
MENU
UNIT OF
PARAMETER
SETTINGS
MEASURE
Internal
kPa
Setpoint
External
kPa
Setpoint
UNIT OF
SUB MENU
PARAMETER
MEASURE
Motor Phase
_
Connection
Type
Motor Type
Service Factor
A
Amps
Min Frequency
Hz
Max Frequency
Hz
Max Sensor
kPa
Value
14
PENTEK IntelliDrive
Owner' s Manual
VALUE
DESCRIPTION
DEFAULT
MIN
MAX
Main pressure setpoint used.
668 kPa
Sets main system operational
(Max
pressure. This parameter is
Sensor
414 kPa
103 kPa
accessed here, through PSI
Value
Preset button, or by pressing
minus 30
Enter button while in Constant
kPa)
Pressure operation.
Second pressure setpoint.
When another pressure
setting is desired other than
Max
Internal Setpoint. Additional
Sensor
programming needed in I/O
276 kPa
103 kPa
Value
section. Requires an external
minus 20
switch or timer to wired to
kPa.
I1 or I2 terminals. It is only
active when there is voltage
present I1 terminals (see
Figure 11)
DEFAULT
MAX
MIN
DESCRIPTION
Selects phase of motor to be
operated. An additional sub
1
3
1
menu will appear, based on
phase selection, to select
proper motor type.
Wire type for 1 phase motor
operation only. Can only access
3 wire
3 wire
2 wire
by first setting Motor Phase
parameter to 1 Phase.
Motor type for 3 phase, 220V,
Above
motor operation only. Can only
Subm
Subm
Gnd
access by first setting Motor
Phase parameter to 3 Phase.
Service factor amps (max.
Per drive
load) of motor the Drive is
00.0 A
00.0 A
and
operating. Sets maximum
motor
allowed amps at output of
Drive. See Table 7 for values.
1 below
Minimum frequency (speed)
30 Hz
30 Hz
Max Hz
motor will run.
1 above
Maximum frequency (speed)
50 Hz
Hz
Min Hz
motor will run.
Maximum pressure value of
transducer sensor used with
689 kPA
2068 kPa
68 kPa
Drive. Only change if different
transducer is used with Drive,
other than 689 kPA max scale.
TABLE 9 (CONTINUED)
MENU OR
UNIT OF
PARAMETER
SUB MENU
MEASURE
DEFAULT
Excessive
Runtime
_
Enabled
Detection
Excessive
Hours
24
Runtime Hours
Auto Restart
Minutes
10 Min
Delay
Number of
3
Resets
Detection Time
M:SS
15 Sec
Sensitivity
kPa
68 kPA
Fill Time
M:SS
1 M
Digital Input 1
Unused
Digital Input 2
Relay Output
Unused
Over Pressure
kPa
552 kPa
No Ground
Enabled
Detection
Factory Reset
No
Software
Disabled
Update
PROGRAMMING
VALUE
DESCRIPTION
MIN
MAX
Enables or disables Excessive Runtime
Disabled Enabled
Detection.
Number of hours Drive can run before it
1
100
faults on Excessive Runtime.
Time Drive waits to restart pump when
3 Min
60 Min
Dry Run is detected.
Number of tries Drive attempts to
0
5
restart pump when Dry Run condition
is detected.
Time the Drive takes to recognize Dry
5 Sec
10 Min
Run condition.
Pressure value that Dry Run condition
is detected at. Dry Run fault will
2068
0
occur if this pressure cannot be met
kPa
within Detection Time window. Lower
pressure = less sensitivity.
Time allowed to fill (prime) pipes during
Auto Line Fill process. Relates to Dry
15 S
10 M
Run Sensitivity value. (Time starts after
55 Hz is reached).
Selects operation of Drive when
terminal I1 is used. Select between
Unused, Run Enabled, Ext Fault, and
Setpoint. The Drive will respond to
selected command when voltage is
present at I1 terminal.
Selects the operation of Drive when
terminal O1 is used. Select between
Unused, Run, and Fault. The Drive
closes the Relay when Run or Fault is
selected.
Sets Over Pressure Warning value.
2047
103 kPa
Change if higher than 552 kPa system
kPa
pressure is needed.
Selects whether Ground Detection
parameter is Enabled or Disabled. If
Disabled is selected, it will revert back
Disabled Enabled
to Enabled after 72 hours. Warning LED
will flash entire time it is Disabled.
Resets all parameters to factory
defaults. Displays Setup Guide after it is
No
Yes
complete. Software version displayed
here. Does not clear fault log.
Disabled Enabled Used to update software, if necessary.