DESCRIPTION

Specifications/Ratings
Input Voltage........1-Phase 230VAC Nominal (190–265VAC)
Input Frequency....................................................50/60Hz
Ambient Temperate Range............................-20° to 50 °C
Output Connections........................3-Phase, 3-wire, 220V
.................................................................3-Wire/1-Phase
..................................................................1-Phase/2-wire
Max Motor Cable Length...........................................305m
Enclosure.....................................................................3R
Table 1 - Specifications
Max
Input
Motor
Model
kW
Phase
Operation
PID2000-
2-wire, 3-wire
1.5
1
1123
& 3-phase
The PENTEK INTELLIDRIVE is specifically designed to
operate 4" submersible pumps and 3-phase, 220V above
ground pumps in water well and residential booster
applications. Each Drive is rated for maximum output
amp rating. Any use of Drive outside of intended design
parameters will void warranty. If Drive is used with above
ground motors not rated for a Variable Frequency Drive,
maximize motor life by limiting lead length to 8m. Refer
to pump Owners Manual and AS/NZS 3000 for proper
wire size.
Figure 1 - A typical residential installation layout
4
PENTEK IntelliDrive
Owner' s Manual
Each carton contains:
• PENTEK INTELLIDRIVE Variable Frequency Drive
• Pressure Transducer
• 3m Pressure Transducer Cable
• Quick Start Guide
• Owner' s Manual
PID2000 - 1
1
2
3
Product Family
Max
PID - PENTEK INTELLIDRIVE
Amps
13.5
Voltage Rating:
1 = 190-265 Volt 1 phase input
Output voltage:
1 = 230v 1 phase output
HP Rating:
Type:
2 = 2.0 HP
Transducer
The PENTEK INTELLIDRIVE uses a 4-20mA,
0-668 kPa pressure transducer to control
motor speed (max is 2068 kPa transducer).
The transducer (see Figure 1) senses
pressure in the pipe and converts it to an
electrical signal. The Drive senses and
processes the signal in the PID (Proportional,
Integration, Derivative) control. When
operating in AUTOSTART mode, the Drive
increases and decreases the speed of the
pump motor as needed to maintain constant
pressure in the piping system.
Changes internal pressure setpoint
Motor
from 103 kPa to transducer max
3 = 3-wire
Runs the Drive at 45Hz (with no
pressure control) to allow installer
Changes display to previous screen.
Selects menu items and confirms
numeric value changes.
Power is ON to Drive.
Drive is in Warning Mode (TPM);
refer to Troubleshooting section.
Displays Drive' s current operating
condition and changes display
Figure 2 - PENTEK INTELLIDRIVE keypad functions
Keypad
The keypad programs the Drive, monitors the
status of the pump, and displays faults if they
occur. Each button has a unique function, as
described in Figure 2. The LCD display shows
a text display of the status of the Drive' s
operation. Other LEDs light up to indicate
when certain buttons are pressed or certain
events occur.
Fan
The Drive uses a thermostatically controlled
internal fan which operates automatically
when necessary to cool the Drive components.
-20 kPa . ie 2047kPa
to pump out well.*
A fault has
occurred.
parameters.
Stops the
motor.
DESCRIPTION
Views and changes
parameters.
Shows last 15 faults.
With code, locks and
unlocks password
protected keys.
Toggles between English,
Spanish, and French
(default is English).
Left and right arrows move cursor.
Up and down arrows scroll through
menus and change numeric values.
Resets fault that
stopped Drive/pump.
Checks for line fill, then starts pump
6007 0412
in constant pressure mode.
5
PENTEK IntelliDrive
Owner' s Manual