QUICK START GUIDE

Drain

DRAIN CONNECTION
CAUTION
!
The floor drain must be large enough to
accommodate drainage from all attached drains.
Follow these guidelines when installing drain
lines to prevent water from flowing back into
the ice maker storage bin and/or potentially
flowing onto the floor, which may result in
personal injury or property damage
NOTICE
Drain can NOT be located directly below the
unit. Unit has a solid base that will not allow the
unit to drain below itself.
There is a possibility that hose connections may
have loosened during shipment.
Verify all connections and fittings are free from
leaks.
CAUTION
!
This equipment is to be installed with adequate
backflow protection to comply with applicable
federal, state and local codes
CAUTION
!
Failure to connect water supply or drain line
connections properly can result in personal injury
and property damage. Gravity drain connections
must be routed downward from the rest of the
unit at the rate of 1/4" per foot (1 cm per 50 cm).
FACTORY INSTALLED DRAIN PUMP
If your drain line will run up to a stand pipe, disposal
or spigot assembly, or does not otherwise meet the
requirements for a gravity drain, you may have ordered a
pre-installed U-Line P60 drain pump.
If you need to install a P60 drain pump into your unit, see
DRAIN PUMP section in the User Manual.
See below for typical installations requiring a drain pump.
Disposal Assembly
P60 Pump Required
(Optional Hook-Up)
Y-Branch Tailpiece
P60 Pump Required
Air Gap
(Optional Hook-Up)
NOTICE
The maximum lift for the P60 drain pump is
10 feet. This must be done as close to the rear of
the unit as possible.
9
Shut-Off
Valve
Hot
Water
Waste
Air Gap
Hot
Water
Shut-Off
Waste
Shut-Off
Valve
Hot
Water
Water
u-line.com
Waste
Cold
Water
Waste
Cold
Water
Valve
Cold