3.
Line up shelf slide with slide brackets and push shelf
in all the way. Pull shelf outward all the way to make
sure locks are engaged.
Install top hinge and door:
1.
Install hinge with longer straight edge aligned to
outside edge of cabinet. Do not tighten.
2.
Rotate door 180
and set on bottom hinge.
o
3.
Align edge of the hinge with the outer edge of the
unit.
4.
Tighten three hinge screws.
Align and adjust the door:
Align and adjust the door (see DOOR ALIGNMENT AND
ADJUSTMENT)
Install grille and hinge cover
Door Adjustments
USER GUIDE
USER GUIDE
SAFETY • INSTALLATION & INTEGRATION • OPERAT
Door Adjustments
1 CLASS INTEGRATED DOOR REFRIGERATOR
DOOR ALIGNMENT AND ADJUSTMENT
Align and adjust the door if it is not level or is not
sealing properly. If the door is not sealed, the unit may
not cool properly, or excessive frost may form in the
interior.
NOTICE
Properly aligned, the door's gasket should be
firmly in contact with the cabinet all the way
around the door (no gaps). Carefully examine
the door's gasket to ensure that it is firmly in
contact with the cabinet. Also make sure the
door gasket is not pinched on the hinge side of
the door.
To align and adjust the door:
1. Loosen (do not remove) top and bottom hinge screws.
2. Align door squarely with cabinet.
3. Make sure gasket is firmly in contact with cabinet all
the way around the door (no gaps).
4. Tighten bottom hinge screws.
5. Tighten top hinge screws.
REVERSING THE DOOR
Location of the unit may make it desirable to mount the
door on the opposite side of the cabinet.
The lower hinge and hardware will be removed and
installed on the opposite side of the cabinet. The upper
hinge will be replaced with the alternate hinge supplied
with the unit.