6 Door Swing Dimensions

All units have a zero clearance for the door to open 90°. U-Line
recommends a minimum door clearance of 2" to accommodate
the handle if the unit is installed next to a wall.
Wall
1/4" Min.
21-3/4"
16-1/2"
90
Door Swing
Black and White
Wall
CLRCO2160
1/4" Min.
21-3/4"
25-1/2"
90
Door Swing
Black and White
Wall
CO1175
1/4" Min.
20-7/8"
25-1/2"
90
Door Swing
Black
Wall
CO2175
1/4" Min.
21-7/16"
25-1/2"
90
Door Swing
Black and White
CLR2160
Wall
2-1/8" Min.
21-3/4"
16-1/2"
90
Door Swing
Stainless Steel
Wall
2-1/8" Min.
90
Door Swing
Stainless Steel
Wall
2" Min.
20-7/8"
25-1/4"
90
Door Swing
Stainless
Wall
2-1/8" Min.
21-7/16"
25-1/2"
90
Door Swing
Stainless Steel
Door Swing Dimensions

Other Site Requirements

Side-By-Side Installation

For a complete refreshment center, install two units side by side:
Cut-out width for a side-by-side installation is the total of the
widths listed under Cut-Out Dimensions in each unit's Installation
Guide.
No trim kit is required. However, 1/4-inch space needs to be
maintained between the units to ensure unobstructed door swing.
Units must operate from separate, properly grounded electrical
21-3/4"
receptacles placed according to each unit's Electrical Specifications
Requirements

Power Supply

The unit requires a grounded and polarized 115 VAC, 60 Hz, 15A
circuit (normal household current). See Electrical Specifications.
25-1/2"

Water Supply

The unit requires a 1/4" O.D. soft copper supply line, or flexible
water supply kit from U-Line (Part No. WATERHOOKUP).

Drain

The CLR2160 & CLRCO2175 require access to either a gravity or
pump fed drain.

Environmental Requirements

The units are designed to operate between 50°F (10°C) and 100°F
(37°C). High ambient temperatures (100°F [37°C] or higher) may
reduce the unit's ability to reach low temperatures and may also
reduce the ice production rate for those models with ice makers.
If the ambient temperature is expected to drop below 45°F (7°C),
drain all water from the unit to prevent freezing damage, which is
not covered by the warranty.
For best performance, keep the unit out of direct sunlight and
away from heat generating equipment.
For best performance and life outdoors, place under a counter or
provide shelter of some kind.
In climates where high humidity and dew points are present,
condensation may appear on outside surfaces. This is considered
normal. The condensation will evaporate when the humidity drops.
CO29
1/4" Min.
21-7/16"
22-3/8"
90°
Door Swing
5