Sharp AR-FX7 Service Manual page 66

Digital multifunctional system option
Hide thumbs Also See for AR-FX7:
Table of Contents

Advertisement

SW76 No. 1–No. 8 Inhibited to use.
SW77 No. 1–No. 8 Inhibited to use.
SW78 No. 1–No. 8 Inhibited to use.
SW79 No. 1–No. 8 Inhibited to use.
SW80 No. 1–No. 8 Inhibited to use.
SW81 No. 1–No. 8 Inhibited to use.
SW82 No. 1 CI signal ON time in V.8 mode
Used to set the CI signal ON time in V.8 mode.
Default: 0 (9 bytes)
SW82 No. 2 CI signal OFF time in V.8 mode
Used to set the CI signal OFf time in V.8 mode.
Default: 0 (1sec)
SW82 No. 3 Inhibited to use.
SW82 No.4, No.5 CI receive number to shift to non-V.34
communication
Used to set CI receive number to shift to non-V.34 communication.
Default: 1 0 (2 times)
SW82 No.6–No.8 CI send number to shift to Non-V.34
communication
Used to set CI send number to shift to non-V.34 communication.
Setup is made in the range of 0 – 7 by binary input.
When set to 0, retrain is not made.
Default: 2
SW83 No.1–No.8 Inhibited to use.
SW84 No.1–No.8 Inhibited to use.
SW85 No.1–No.8 Inhibited to use.
SW86 No.1 Inhibited to use.
SW86 No.2, No.3 CI detection
Used to set the frequency to detect CI signal which is the calling signal
as follows:
bit
2 3
0 0
: 4 sine wave
1 0
: 3 sine wave
0 1
: 2 sine wave
Default: 0 0 (4 sine wave)
SW86 No.4, No.5 CI delete max. OFF time
Used to set the max. wait time from detection of CI signal pulse (num-
ber of times) to the next CI signal pulse detection. If next CI signal
pulse is not detected within this time, the number of calls up to now is
cleared.
The setup items are as follows:
bit
4 5
0 0
: 5sec
0 1
: 10sec
1 0
: 15sec
1 1
: 20sec
Default: 0 1 (10 sec)
SW86 No.6–No.8 CI signal ON detection enable time
Used to set the time to judge that CI signal is ON.
The CI signal of less than this setup time is not regarded as ON.
The set range is 0 (155ms) – 7 (225ms) in the increment of 10ms.
Default: 155ms
SW87 No.1–No.7 CI signal OFF detectable time
Used to set the min. OFF time for judgment of CI pulse (16Hz call sig-
nal). When OFF time continues for more than the set time, it is judged
as 1 pulse of CI.
The set range is 0 to 1270 by binary input of "N × 10ms".
Default: 1200ms
SW87 No. 8 Inhibited to use.
SW88 No.1–No.8 Inhibited to use.
SW89 No. 1–No.8 Inhibited to use.
SW90 No. 1–No.8 Inhibited to use.
SW91 No. 1–No.8 Inhibited to use.
SW92 No.1–No.8 Inhibited to use.
SW93 No.1–No.8 Inhibited to use.
SW94 No.1–No.8 Inhibited to use.
SW95 No.1–No.4 Inhibited to use.
SW95 No.5–No.8 T1 timer setup
Used to set time-out time from phase B to detection of signal.
T1 time-out time is set in the range of 15 – 90sec (in the increment of
5sec).
Default: 40sec
SW96 No.1, No.8 Inhibited to use.
SW97 No.1–No.8 Inhibited to use.
SW98 No.1–No.8 Inhibited to use.
SW99 No.1–No.8 Inhibited to use.
SW100 No.1–No.8 Inhibited to use.
SW101 No.1–No.8 Inhibited to use.
SW102 No.1–No.8 Inhibited to use.
SW103 No.1–No.8 Inhibited to use.
SW104 No.1–No.8 Inhibited to use.
SW105 No.1–No.8 Inhibited to use.
SW106 No.1–No.8 Inhibited to use.
SW107 No.1–No.8 Inhibited to use.
SW108 No.1–No.8 Inhibited to use.
SW109 No.1–No.4 Print lead edge adjustment (Left edge
adjustment)
Setup of print image area void
The quantity of void at the left edge in main scan direction can be
adjusted. When the set value is increased, the image void is increased.
Setup of SIM 50-9 is reflected.
0 to ±112 dots in the interval of 16 dots
Default: 48 dots
SW109 No.5–No.8 Print lead edge adjustment (Lead edge
adjustment)
Setup of print image area void
The quantity of void at the lead edge in sub scan direction can be
adjusted. When the set value is increased, the image void is increased.
Setup of SIM 50-9 is reflected.
0 to ±112 dots in the interval of 16 dots
Default: 48 dots
AR-FX7 SOFT SWITCH 7 - 39

Advertisement

Table of Contents
loading